LG FM57AH (15.5 kW) - three-phase multi-system outdoor unit for 9 indoor units

CL-000939
325 44000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG FM57AH

The FM57AH: 15.5 kW, three phases, up to nine units

The FM57AH is the largest model in this LG multi range: 15.5 kW cooling, 17.4 kW heating, a three-phase 380 V, 50 Hz supply, R410A refrigerant and a Dual Inverter compressor. The casing is 950 mm wide, 1380 mm high and 330 mm deep, built of metal with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. According to the manufacturer the system serves up to nine indoor units - a whole floor, a small building or premises with a large number of separate rooms. The single-phase equivalent is the FM56AH (item 1862), but at 15.5 kW a single-phase supply is already working at its limit, so where three phases exist this is the model to choose.

Why the three-phase version is all but obligatory at this capacity

15.5 kW from one phase is technically possible but keeps the building under constant strain: a high running current, a thick cable, a skewed balance and breakers working close to their rating. The three-phase version spreads the same load across three phases, and the consequences are simple: a smaller cable, an even balance, protection working calmly and headroom left for other equipment. On a large site this is not merely an electrician's comfort: it is precisely an overloaded phase that causes the trips which stop the climate system at the worst moment. The second advantage is the future: premises with nine rooms live and change, and within two years new equipment appears that needs power. So for new projects at this scale we recommend a three-phase connection as the baseline rather than an option.

Nine rooms: what kind of premises these are

Nine indoor units means a business-centre floor of offices, a dental practice with several surgeries and a waiting area, a hotel of eight or nine rooms, a restaurant with differently used dining areas, or a language school with classrooms. What such premises share is a large number of smallish rooms with their own patterns of use, which one big machine on ductwork cannot serve. What they share as a problem is simultaneity: if all nine rooms are occupied during the same hours, the system is sized without exceeding the outdoor capacity; if they are used in turn, an overlap is acceptable and even advantageous. The third factor is people: in a classroom or a waiting area the heat contribution of those present can exceed all the other loads combined. Premises like this are calculated room by room, with measurements and a usage schedule - ordinary engineering work rather than sizing by floor area.

Restaurants and kitchens: where a multi system does not belong

In a restaurant a multi system works well in the dining areas, but the kitchen is a different problem, and trying to solve it with an air conditioner is a mistake. In a kitchen the point is not cooling but removing heat and fumes through powerful extract ventilation with make-up air, because it is the air change that sets working conditions. An air conditioner in such a room quickly clogs with grease, loses efficiency and becomes a source of smell, even with frequent filter cleaning. The correct arrangement is dedicated ventilation for the kitchen, with the multi system serving the dining areas, the bar, the offices and back rooms where nothing is cooked intensively. In the dining areas the position of the units matters: the airflow is not aimed at tables, because cold air on a guest's back ruins an evening faster than heat does, and the correlation with complaints is direct.

A design, not an equipment list

On premises of this scale a working design is needed before purchase, and that is not bureaucracy but a way of avoiding paying twice. A design includes: load calculations room by room, the layout of indoor units with airflow directions, the main line schematic with branch joints and distribution boxes, the drainage layout with discharge points, electrical loads and board requirements, and the outdoor unit's position with service access. With that document you compare different contractors' offers for the same scope of work rather than for equipment prices. The second value of a design is approvals: with the building owner, with the landlord, with fire requirements where partitions are penetrated. The third is operation: in five years those drawings are worth more than any accessory, because without them the next installer works blind.

Commissioning a large system

Commissioning a nine-unit system is a distinct stage of several hours, and it is not combined with the last day of installation. The sequence is standard: nitrogen pressure testing with a hold period, evacuation with a vacuum hold test, calculating and adding the extra refrigerant for the actual pipe lengths, testing each indoor unit separately and then all of them together. That last point is what shows whether the capacity was chosen correctly: a system that holds every room well on its own may not cope under full load. The drains of every unit are also tested by pouring water into the tray, along with the phase sequence and the automatic restart after a power failure. All readings go into a record - the baseline against which the system's condition is compared a year later.

Who is responsible for the climate system on site

On large premises equipment fails not from working but from having no owner. The practice is simple: one person should be responsible for the climate system - an administrator, a technician or a department head. Their tasks are small: check the indoor filters once a month, make sure the drains are flushed before summer, and call the service engineer on schedule twice a year. Second, a log: the date, what was done, which readings; from that log the engineer sees trends and the owner sees whether the regime is being followed. Third, rules for staff: do not stack boxes under indoor units, do not block grilles, do not set 17 degrees in the hall. These simple things add years to a system's life, and they cost less than any repair.

When to look at a different class of system

A nine-unit multi is the limit of the range, and there are situations where another class of equipment deserves consideration. First, the need for different modes at the same time: if one part of the building needs cooling while another needs heating on the same day, that is a task for heat recovery systems, not for multi splits. Second, more than nine rooms, or staged expansion over years: here the flexibility of VRF systems with a main-line distribution wins. Third, the need for full building heating: then the direction is Therma V heat pumps (items 1877-1887) with a water circuit, radiators or underfloor heating. Fourth, two independent parts of a site: two smaller multi systems are often more reliable and more flexible than one at maximum. We raise these alternatives before the sale, because replacing a wrongly chosen system a year later costs more than all the savings of a hasty decision.

Send the list of rooms with their areas, operating hours and occupancy, together with the parameters of the three-phase supply, and we will calculate the load per zone and prepare a specification with branch boxes, drainage and electrical requirements. If the site is larger or the rooms need different modes, we will say honestly where a multi system is no longer the optimum.

Characteristics LG FM57AH

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
380В.
Feeding
Number of phases
3
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
53
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R410A
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
1380 мм.
Outdoor unit length
330 мм.
Outdoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
15500 Вт.
Thermal efficiency
17400 Вт.
Find similar

Reviews about LG FM57AH from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку