Solplanet ASW 06kH-T2 - three-phase hybrid inverter 6 kW
Please sign in so that we can notify you about a reply
Description Solplanet ASW 06kH-T2
Characteristics Solplanet ASW 06kH-T2
AC connection
Plug-in connector
Battery type
LiFePO4
Battery voltage range
from 120V to 600V
Communication with BMS
✓
Compatible battery
Aiswei Ai-HB G2 Series
DC connection
Plug-in connector
Installation type
Wall bracket
Max. charging / discharging power
6000 W / 6000 W
Max. charging current / Max. discharge current
30A
Max. switching time
≤ 10 ms
Maximum efficiency / European efficiency
97.5% / 98.2%
Maximum total output power
4000W / 2000W
MPPT efficiency
99.9%
Noise level (typical)
< 35dB
Nominal input current from the network
17.4A
Nominal network voltage
3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V
Operating temperature
- 25°C … +60°C
Power
6 kW.
Power factor at nominal power / adjustable volume
9000 Wp
Type
Hybrid
AC output parameters
AC mains frequency/range
45 ~ 55 Hz / 55 ~ 65 Hz
Adjustable power factor range
3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V
Allowed AC voltage range
from 270 V to 480 V / 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V
Harmonic distortion (THD) at rated power
< 3%
Maximum output current
9.6A.
Maximum peak power
12000VA.
Rated AC voltage
3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V
Rated full power
6000VA.
Rated output current
8.7A.
Communication
Communication interface
Wi-Fi / LAN
DC input parameters
Maximum input voltage
1100V.
Maximum operating input current
17.4A.
Maximum short-circuit current
30A.
MPP voltage range
150V. to 950V. / 630V.
Number of independent MPPT inputs/strings per MPPT input
2/1
Starting voltage
60V. / 180V.
Feeding
Number of phases
3
Functionality
Cooling concept
Natural convection
Ground fault monitoring / network monitoring
✓
LED indicators (status/fault/communication)
✓
Management
Mobile app
Possibility of integration with third-party automation systems
✓
Surge protection
Type II
General characteristics
Country of origin
People's Republic of China
Country of origin
Germany
Guarantee
10 years
Topology
without a transformer
Manufacturer
Solplanet
Operating conditions
Maximum permissible relative humidity (non-condensing)
100%
Maximum working height
4000 m.
Operating temperature range
-25°C … +60°C
Overall dimensions
Depth
205 mm.
Height
465 mm.
Width
545 mm.
Physical properties
Height
465 mm.
Weight
24.5 kg.
Protection
DC reverse polarity protection/short circuit protection
✓
Degree of protection (according to IEC 60529)
IP66
Protection against jumps
✓
Reviews about Solplanet ASW 06kH-T2 from real users
No reviews found
Store addresses
Working hours
Телефон
Availability
Smila
Uman