Dialan UTP Cat.5 2-pair 0.50 CCA outdoor LAN cable
Description Dialan UTP Cat.5 2P
Two-pair twisted pair for outdoor lines
Dialan UTP CAT 5 2P 0.50 mm CCA outdoor is an unscreened category 5 cable with just two pairs, in polyethylene insulation, for routes outside buildings. The 0.50 mm conductor is aluminium clad in copper, the diameter over the insulation 0.9 mm, the impedance 100 ± 15 ohms and the direct-current conductor resistance no more than 15 ohms per 100 metres. The operating range is -40 to +60 °C and installation from -10 °C. The permissible tensile force is only 50 N — the lowest in the whole LAN range, and a direct consequence of there being only two pairs.
Pair arithmetic: what works on two and what does not
The old ten-megabit network and hundred-megabit Ethernet use only two of the four pairs — one to transmit, one to receive. That is why a two-pair cable still exists: at those speeds it is electrically complete. Gigabit, however, is built differently: it engages all four pairs at once, in both directions on each. On a two-pair line a gigabit port simply will not come up, or drops to a hundred megabits. This is not a question of cable quality and not something that can be configured: the conductors needed are physically absent. There is a detail of installation too: hundred-megabit Ethernet uses contacts 1–2 and 3–6 of the connector, so the two pairs must be wired into exactly those positions rather than any four convenient contacts, or the link will not come up at all.
Power over two pairs
The classic modes of power over twisted pair do work on two pairs, so such a line will feed a camera or an access point of modest appetite. But the modern high-power modes spread the current over all four pairs precisely in order to reduce heating — and on a two-pair cable they are unavailable. Add a bimetallic conductor with its raised resistance and the voltage margin becomes slim indeed. The conclusion is simple: a two-pair cable with power suits only a short line and undemanding equipment.
Fifty newtons means pulling gently
A permissible tensile force of 50 N is roughly the weight of five kilograms. Pulling such a line through a duct for a few tens of metres, the force is easy to exceed without noticing: the cable does not break, but the pairs stretch and the twist pitch changes for good. The pull should be smooth, with lubricant or a draw tape, preferably with two people — one feeding, one pulling. And certainly without jerks at corners, because that is where the force on the cable rises most sharply.
Where this is enough
A two-pair outdoor cable is a working answer for a single camera at the gate, a door entry panel, a barrier, a hundred-megabit line to the building next door, analogue telephony, sensors and access controllers. Where the line might one day be needed for a gigabit or for heavy power, saving on two pairs turns into a second pull. The cable is not self-supporting: an aerial span needs the version with a messenger, and the ground needs a duct along the whole length.
Tell us what will sit at the end of the line and whether a gigabit might ever be needed there: we will say where two pairs suffice for good and where four are the better start.
Characteristics Dialan UTP Cat.5 2P
Reviews about Dialan UTP Cat.5 2P from real users
No reviews found