Dialan U/FTP Cat.6A 4-pair outdoor LAN cable
Description Dialan U/FTP Cat.6A PE
An outdoor cable with a screen on every pair
Dialan U/FTP 4Pr Outdoor Cat.6A is a four-pair category 6A cable in which every pair has its own screen, there is no overall screen, and the outside is a sheath of black light-stabilised polyethylene. A tinned copper drain wire of 0.4 mm runs through the centre of the core, and an overlapping PET-E belt film holds the core together. The insulation is solid polyethylene, the impedance 100 ± 15 ohms, the mutual capacitance no more than 56 nF/km, the insulation resistance at least 5 GΩ/km, the tensile force up to 85 N and the operating range -50 to +60 °C.
Four foil tubes and water
Inside this cable are four separately screened pairs, which is to say four closed tubes of foil. While the sheath is sound that makes no difference. But the moment it is damaged — cut during a pull, bitten through, cracked at an old kink — water gains several paths along the cable at once: capillary movement under foil is quicker than along an open core. There is no water-blocking compound in this construction, so the sheath and the duct remain the water barrier. The practical conclusion: ends are sealed straight away rather than the next day, and a coil is never left on site with an open end under the open sky.
There is nothing to earth here but the drain wire
This variant has no overall screen, so the only metallic element that can be earthed is the drain wire in the centre of the core. It touches all four foil tubes and brings them into one electrical system, so earthing at one end works properly. The cable has no outer metallic envelope, however, and it is less protected against induced lightning voltage than a version with an overall screen. Where the line leaves the building, surge protection on the pairs at the entry is not a wish here but part of the design.
What this card does not state
Plainly: for this item the manufacturer publishes neither an outer diameter, nor a conductor diameter, nor a mass, nor a packaged length, although the indoor U/FTP of the same category has those figures — 6.7 mm and 47.3 kg/km. Close values plus an allowance for the polyethylene sheath are the reasonable expectation, but an assumption has no place in a conduit-fill calculation. If you need exact figures for a design, we will request them from the manufacturer for the specific batch and pass them on in writing.
Which routes it suits
A crossing between buildings where many lines share one duct and mutual influence is what matters; a drop to outdoor equipment near the office wiring; a run across a site with a moderate electrical environment. Where a substation, a welding shop or a traction line is close by, the braided version is the better buy. Installation from -10 °C, and like any outdoor cable this one should end at the building entry: a polyethylene sheath has none of the fire characteristics required for installation indoors.
Describe the route and how many lines share the duct: we will work out the footage, request the exact diameter and mass, and choose the hardware for the entry.
Characteristics Dialan U/FTP Cat.6A PE