Dialan U/FTP Cat.6A 4-pair LAN cable with a screen on every pair
Description Dialan U/FTP Cat.6A
Every pair in its own foil
Dialan U/FTP 4Pr Indoor Cat.6A is a four-pair category 6A cable in which every pair has its own screen, with no overall screen over the core. A tinned copper drain wire of 0.4 mm runs through the centre of the core, and an overlapping PET-E belt film holds the core together. The conductor is solid copper of 0.565 mm, the insulation solid polyethylene, the impedance 100 ± 15 ohms, the mutual capacitance no more than 56 nF/km and the insulation resistance at least 5 GΩ/km. The outer diameter is 6.7 mm, the mass 47.3 or 47.7 kg/km, the operating range -20 to +60 °C. It comes on a plywood reel of 305, 500 or 1000 metres.
The screen sits where the interference is born
An overall screen over the whole core protects the cable from the outside world but does nothing about the main problem at high frequencies: the mutual influence of the pairs inside one sheath. Foil on each pair works the other way round — it separates the pairs from one another, removing the interference at the place where it arises. For category 6A that is the decisive difference, because at frequencies up to 500 MHz internal crosstalk is the hardest parameter to meet. The same foil also cuts off the influence of neighbouring cables in a bundle: four closed screen tubes do that no worse than one common one.
A drain wire in the centre of the core
This is a rare and sensible solution. In cables with an overall screen the drain wire is laid under the screen, because that is where electrical contact has to be made. Here there are four screens and contact is needed with all of them at once, so the wire runs in the very centre, between the pairs, touching every foil tube. The four screens thus become one electrical system with a single point of connection. The practical conclusion for an installer: this wire must not be cut off as surplus — it is the only way to earth this cable’s screens.
The slimmest and lightest in category 6A
Six point seven millimetres against 7.4 for the unscreened U/UTP of the same category and 6.8 for S/FTP. The mass is 47.3 against 52.1 to 53.5. In cross-sectional area that is about a fifth less, so distinctly more lines fit the same duct and the weight of a bundle on a tray comes out appreciably lower. The result is something one does not expect of a screened cable: it is more compact and lighter than the unscreened one, because here the interference is removed by foil rather than by distance between the pairs.
Where it goes, and what to allow for when terminating
Server rooms and comms cabinets, dense trunk runs, offices with many workstations, buildings with old wiring, lines to the newer generation of Wi-Fi access points. Installation from -10 °C, minimum bending radius ten cable diameters. Termination takes longer: the foil of each pair has to be folded back carefully without tearing, and all four plus the drain wire brought onto a screened outlet. The whole line must be screened — outlets, panels, patch cords — otherwise the four screens are simply connected to nothing.
Tell us how many workstations there are and what the channel is: we will say how many such cables fit your duct and what outlets and panels you will need.
Characteristics Dialan U/FTP Cat.6A