Dialan SF/UTP Cat.6 4-pair LAN cable with a double screen
Description Dialan SF/UTP Cat.6
Category 6 with a double screen
Dialan SF/UTP Cat.6 4Pr Indoor is a four-pair category 6 cable in which the core is covered first by aluminium-polymer tape and then by a metallic braid over it. Inside sits a pair separator of polyethylene or LSFRZH, and an overlapping PET-E belt film holds the core together. The conductor is solid copper of 0.57 or 0.54 mm, the outer diameter 7.8 or 7.5 mm, the impedance 100 ± 15 ohms and the mutual capacitance no more than 56 nF/km. It comes on a plywood reel of 305, 500 or 1000 metres, with a choice of PVC, LSZH or LSFRZH sheath.
Why the tape here lies metal-outwards
This is the most interesting detail of the construction, and it is no accident. In screened cables with a single screen the tape is laid metal-inwards, closer to the pairs. Here it is the other way round, metal-outwards, and the reason is simple: the metallised face has to touch the braid lying directly on it. Were the tape turned metal-inwards, the polymer backing — an insulator — would face outwards, and the foil would be electrically divorced from the braid. Instead of one continuous screen there would be two independent ones, one of them floating with no earth at all.
Two screens working as one system
Because the metal touches the braid, foil and braid form a single screen with two different properties. The foil is continuous, without gaps, and therefore reflects high-frequency interference well; the braid has low resistance along the cable and therefore carries away mains-frequency and impulse currents. And it is the braid that provides a proper point of connection: it can be stripped, twisted and clamped under a screw, so no separate drain wire is needed here — the braid itself plays that part, with a far larger cross-section.
Seven point eight millimetres: the thickest cable in the range
For comparison, unscreened category 6 measures 6.0 mm, the foil-screened version 6.9, and this one 7.8. That is roughly 70 % more cross-sectional area than the unscreened variant, so the calculations for conduit fill and tray loading have to be redone. The minimum bending radius is ten diameters, which is now about 8 centimetres, and such a radius simply will not fit a standard outlet box — deep boxes or separate enclosures are needed. The cable is appreciably stiffer and termination takes longer: the braid must be folded back neatly without breaking strands or cutting into the foil.
For which sites it is justified
Production halls with welding, frequency converters and large motors; boiler and pump rooms; lift machine rooms; studios and control rooms; hospital rooms with heavy equipment; server rooms beside power entries. There the spectrum of interference is wide — from mains frequency to the radio bands — and a single screen leaves half of it uncovered. In an ordinary office or flat a double screen does not pay for itself: foil is enough there, and most often so is unscreened cable with a separator.
Describe what equipment stands near the route and what boxes are planned at the workstations: we will say whether a double screen is needed and whether it will fit the boxes you have.
Characteristics Dialan SF/UTP Cat.6