Catalogue

Dialan S/FTP Cat.6A 4-pair braided LAN cable for indoor use

CL-001368
Contact us for a price
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description Dialan S/FTP Cat.6A

Foil on the pairs and a braid over them

Dialan S/FTP 4Pr Indoor Cat.6A is the most complete screening scheme there is: every pair has its own screen and a braid of tinned copper wires lies over the core. A PET-E belt film without overlap wraps the core. The conductor is solid copper of 0.565 mm, the insulation solid polyethylene, the impedance 100 ± 15 ohms, the mutual capacitance no more than 56 nF/km and the insulation resistance at least 5 GΩ/km. The outer diameter is 6.8 mm, the mass 50.3 or 50.7 kg/km, the operating range -20 to +60 °C. It comes on a plywood reel of 305, 500 or 1000 metres.

Why a braid rather than an overall foil

Foil is continuous and reflects high frequencies well, but its resistance along the cable is high — it will not carry away a substantial current. A braid of copper wires is the opposite: low longitudinal resistance, so it can take both mains-frequency current and an impulse. In this cable the division of labour is plain: the pair foils fight crosstalk inside, the braid fights heavy induction from outside. There is a practical detail too: a braid can be stripped, twisted and clamped under a screw, so no separate drain wire is provided here — the braid itself plays that part, and the tinning protects the contact from oxidation.

A 0.5 mm sheath, with colour and marking by agreement

This is the only item in the whole LAN range for which the manufacturer states the sheath thickness: 0.5 millimetres. And the only one where the sheath colour and the marking text are agreed when ordering. On a large site that is a real tool: different colours for different subsystems — workstations, video surveillance, building management — and your own text on the sheath, which stops the cable being substituted during installation or the routes being confused years later. These options are agreed for a production batch, so they are worth raising at the time of ordering rather than after.

The scheme used for the highest classes

S/FTP is not merely "another screening option". It is the same construction on which the highest-class cables are built: foil on each pair plus a braid over them. The installation skills and hardware mastered on this cable will therefore not go to waste in a move to a higher class. And 6.8 mm is less than the 7.4 of the unscreened U/UTP of the same category, so maximum protection does not mean the thickest cable in the duct.

Where it is needed, and about terminating it

Rooms with a harsh electrical environment — workshops, boiler rooms, machine rooms, suites with heavy medical equipment; server rooms with a high density of lines; routes that cannot be kept away from power ones. Installation from -10 °C, minimum bending radius ten diameters, and the cable is stiffer than usual. At each end five screens have to be brought onto a screened outlet — four pair foils and the braid — and done so that the braid neither frays nor shorts the pairs. The whole line must be screened and earthed at one end.

Tell us the batch size, the colour you need and the marking text: we will agree it with the manufacturer and quote it together with the screened hardware.

Characteristics Dialan S/FTP Cat.6A

Ізоляція
суцільна, ПЕ
Діаметр жили
0,565 мм
Довжина в упаковці
фанерна котушка 305/500/1000 м
Екран
обплітка з мідних луджених дротів
Зовнішній діаметр
6,8 мм
Зусилля розтягування
≤ 85 N
Кількість пар
4
Категорія
Cat.6A
Мінімальний радіус вигину
≥ 10 діаметрів кабелю
Місце прокладання
Внутрішнє
Марка кабелю
S/FTP 4Pr Indoor
Маса кабелю
50,3 / 50,7 кг/км
Матеріал жили
мідний дріт
Оболонка
ПВХ, LSZH або LSFRZH, товщина оболонки 0,5 мм, колір оболонки та текст маркування за погодженням…
Опір ізоляції
не менше 5 ГОм/км
Опір жили постійному струму
не більше 75 Ом/км
Поясна ізоляція
плівка ПЕТ-Е, без перекриття
Призначення
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100…
Робоча ємність
не більше 56 нФ/км
Стандарти
ДСТУ IEC 61156-5, ДСТУ EN 50288-10-1, ТУ У 27.3-05758730-097:2018
Стандарти кабельної проводки
ДСТУ ISO/IEC 11801, ДСТУ EN 50173-1
Температура експлуатації
-20 °C … +60 °C
Температура монтажу
-10 °C … +60 °C
Технічні умови
ТУ У 27.3-05758730-097:2018; ТУ У 27.3-36722092-004:2026
Тип екранування
S/FTP
Тип кабелю
LAN-кабелі категорії 6А
Хвильовий опір
100 +/-15 Ом
Швидкість поширення сигналу
80 %
General characteristics
Manufacturer
Dialan
Find similar

Reviews about Dialan S/FTP Cat.6A from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку