Dialan F/FTP Cat.6A 4-pair LAN cable with two levels of screening
Description Dialan F/FTP Cat.6A
Two levels of screening
Dialan F/FTP 4Pr Indoor Cat.6A is a four-pair category 6A cable in which every pair has its own screen and an overall screen of aluminium-polymer tape, metal-inwards, lies over the core as well. A tinned copper drain wire of 0.4 mm runs through the centre of the core, and a PET-E belt film wraps the core without overlap, leaving a gap. The conductor is solid copper of 0.565 mm, the insulation solid polyethylene, the impedance 100 ± 15 ohms and the mutual capacitance no more than 56 nF/km. The outer diameter is 6.9 mm, the mass 50.4 or 50.8 kg/km, the sheath PVC, LSZH or LSFRZH.
Why a cable needs two screens at once
They close off different things. Foil on each pair separates the pairs from one another — that is internal crosstalk, the hardest parameter of category 6A. The overall screen over the core works at the cable’s boundary: it lets no induction in from outside and lets no radiation of its own out. The second half matters less often than the first, but there are places where it is mandatory: rooms with sensitive measuring equipment, medical diagnostic suites, laboratories, sites with information security requirements. There a line must neither listen nor speak.
The gap in the belt film is by design, not an oversight
The specification states that the belt film is laid without overlap, with a gap, and that is easy to take for a defect. Compare the whole category 6A family, though, and a pattern appears: wherever there is no overall screen the film is laid with an overlap; wherever an overall screen exists the film has a gap. The reason is plain — through that gap the overall screen touches the pair foils and the drain wire in the centre. A closed film would insulate the screens from each other, and instead of one electrical system there would be several separate ones.
The price of a second screen is two tenths of a millimetre
Compare three cables of one category: U/FTP measures 6.7 mm, this F/FTP 6.9, and the unscreened U/UTP 7.4. Adding a full overall screen therefore costs 0.2 mm of diameter and about three kilograms per kilometre, while doing without screening altogether costs 0.7 mm — three times as much. For dense routes that is the arithmetic that decides the choice: maximum protection here takes almost no room in the duct.
Where it goes and how it is terminated
Sensitive rooms, server rooms with a high density of lines, buildings with heavy equipment, links carrying ten gigabits over the full hundred metres. The operating range is -20 to +60 °C, installation from -10 °C, the minimum bending radius ten diameters. Terminating one end here means handling six elements: four pair foils, the overall screen and the drain wire, all of which must reach a screened outlet through one reliable contact. That takes longer than on any other cable in the range, and the time belongs in the labour estimate.
Describe the room and the requirements: we will say whether both screens are needed here and quote the set together with outlets and panels.