Catalogue

LG UV48R (48,000 BTU, 13.5 kW) - ceiling-suspended unit for warehouses and production areas

CL-000920
84 52400 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG UV48R

The UV48R: a 13.5 kW ceiling-suspended unit

The UV48R is a ceiling-suspended indoor unit from LG's R32 semi-industrial range, rated at 13.5 kW cooling and 15.5 kW heating. The 1600 by 690 by 235 mm casing mounts directly under the slab: no suspended ceiling, no decorative panel and no ductwork are needed. Supply is 220-240 V, 50 Hz, the refrigerant is R32, the compressor in the pair is a Dual Inverter, the casing is metal with plastic parts, manufacturer country and origin are Korea and the warranty is 24 months. Pipe diameters and the maximum run come from the data sheet for the pair with a specific outdoor unit, as the card does not carry them. This is already the capacity level that covers a large store, a production bay or a sales floor of 130-170 m².

When a ceiling-suspended unit is the only option

There are spaces where the choice between unit types does not really exist. The first is a building with exposed structure and services overhead that nobody intends to cover: warehouses, hangars, workshops, loft-style interiors. The second is a space whose ceiling void is less than 300 mm, where a cassette or a ducted unit physically will not fit. The third is a hall with glass walls from floor to ceiling, where there is nowhere for a wall unit and the ceiling is decorative and load-free. In each case the UV48R hangs on four rods from the structure and starts working - with no negotiation with the ceiling designer and no alteration to the interior. That is exactly why it is chosen in refurbishments, where any intervention in the structure brings a separate design with it.

Warehouses: storage temperature rather than human comfort

In a warehouse air conditioning is often installed for the goods rather than the staff: medicines, cosmetics, electronics, chocolate, wine and paints all have storage temperature limits. The task differs from an office: not comfort but stability - the temperature has to stay within a narrow band around the clock, including nights and weekends. That changes the sizing approach: you want a margin for an exceptional heatwave rather than a calculation for average conditions, and redundancy is desirable, because a day of downtime can cost an entire consignment. The second feature is distribution: goods on the top rack levels sit at a very different temperature from those at the bottom, and the horizontal stream of a ceiling unit is what mixes the volume. For such sites we calculate not only capacity but the circulation pattern between the racks.

Aiming the stream between racking

In a racked space the stream has to run along the aisles, not across them: a row of racking three or four metres high stops the flow instantly and the next aisle gets no air at all. The unit hangs at the end, blowing down the longest clear corridor, and where necessary a second unit serves a parallel aisle. If the racking layout is not yet fixed, this is the rare case where it is worth coordinating it with the climate design from the start: aisles oriented the right way cost less than an extra unit. The check is simple - walk the store with an anemometer a month after start-up and measure the air speed in the far aisles; if it is close to zero, part of the volume is not being ventilated at all. In temperature-controlled storage that is not a comfort question but a matter of meeting the conditions written on the product documentation.

The outdoor unit on an industrial roof

The pair for the UV48R is the single-phase UU48WR (item 1818) or the three-phase UU49WR (item 1822) at 13.5 kW cooling and 15.5 kW heating. In a warehouse or workshop the outdoor unit usually goes on the roof, and a few practical rules apply. The frame is raised above the roof surface so as not to breach the waterproofing or leave the unit standing in water during downpours, and pads under the feet spread the load across the roof build-up. Clearances to parapets and neighbouring plant follow the manual, or hot air starts returning to the condenser and capacity drops away in a heatwave. The pipe run down goes in a protected shaft or a steel tray with UV-resistant insulation: ordinary insulation on an open roof crumbles within two or three seasons.

An inverter in continuous duty

A warehouse or a factory runs around the clock, and it is in that duty that an inverter pair shows its advantage most clearly. Instead of switching to full output and stopping, the compressor matches its capacity to the actual load and holds the temperature steadily, without swings of two or three degrees. For goods with temperature requirements that is not about comfort but about compliance with storage conditions. The second effect is service life: the number of compressor starts is an order of magnitude lower than in older direct-start designs, and starting is the hardest duty any compressor faces. The third is electrical: starting currents are small, so the equipment fits more easily into an existing supply and does not dip the voltage at the moment it begins.

Monitoring and failure alerts

For temperature-controlled storage what matters is not only the cooling but how quickly you learn that it has stopped. The basic level is the AC Smart 5 central controller (item 1907), which shows the state of every unit, keeps an alarm log and supports BACnet IP and Modbus TCP for passing data to a building management system. Connecting outdoor units into such a network uses the PI485 PMNFP14A1 module (item 1904). Where there is no building management system, the minimum is an independent temperature sensor in the room with GSM alerting: it does not replace a controller, but it does ring at night when the temperature goes out of band. Experience shows most warehouse losses do not come from equipment failing as such, but from the failure being discovered on Monday morning.

Tell us what you store or produce and within which temperature range, and we will size the system with a margin for an exceptional heatwave and lay it out around your aisles. Where it is warranted we will propose redundancy and monitoring so that a stoppage reaches you immediately.

Characteristics LG UV48R

Installation type
Стельовий
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Напівпромисловий
BTU
46
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
690 мм.
Indoor unit length
235 mm.
Indoor unit width
1600 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
13500 Вт.
Thermal efficiency
15500 Вт.
Find similar

Reviews about LG UV48R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку