LG UV42R (42,000 BTU, 12 kW) - 1600 mm ceiling-suspended unit for workshops and halls

CL-000919
81 36000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG UV42R

The UV42R: a 12 kW ceiling-suspended unit

The UV42R is a ceiling-suspended indoor unit from LG's R32 semi-industrial range, rated at 12 kW cooling and 13.5 kW heating. The casing is the same as the UV36R's: 1600 mm wide, 690 mm deep and 235 mm high, mounted straight under the slab with no suspended ceiling and no decorative panel. Supply is 220-240 V, 50 Hz, the refrigerant is R32, the compressor in the pair is a Dual Inverter, the casing is metal with plastic parts, manufacturer country and origin are Korea and the warranty is 24 months. Pipe diameters and the maximum run are not on the card: they follow from the specific pair, and we supply them from the combination data sheet. The two extra kilowatts over the UV36R come without a larger casing, through a denser coil and a higher airflow.

12 kW where a small area holds a lot of heat

Judged by floor area alone, 12 kW looks excessive for an average hall - but area is rarely the main factor in the spaces that ceiling-suspended units are bought for. A 120 m² gym with twenty people exercising, a print shop with machinery running all day, a bakery with an oven behind the wall, a server room in a shopping centre: in all of these the load comes from what is inside rather than from the walls and roof. A person exercising hard gives off several hundred watts, an industrial printer about a kilowatt, refrigeration equipment the heat of its condensers. Once those sources are added up honestly, 12 kW over a hundred square metres turns out to be a requirement rather than a margin. That is why we always ask for a list of the equipment in the room, not just its dimensions.

Two units in a wide hall: how to orient them

When one unit cannot cover a hall, two are installed, and there is a classic mistake here - hanging them facing each other so the streams meet in the middle. That is best avoided: opposing flows cancel each other where they meet, rise, and produce turbulence instead of even distribution. Two arrangements work: either both units go on the same wall, spaced apart and blowing in the same direction, or they are set diagonally so the streams run parallel and offset. In a wide workshop a further option is units on the long walls blowing along the space, which sets up a circulation that takes in the whole volume. The final decision comes from a plan with the equipment on it, because what breaks a stream is not the wall but whatever stands in its path.

Vehicle workshops: life in an open bay

In a service bay a ceiling-suspended unit is convenient because it hangs under the slab, takes no wall space from tools and is in no danger of being caught by a trolley. The difficulty lies elsewhere - the doors: every opening for a vehicle undoes half an hour of the air conditioner's work, so the unit is oriented to blow into the depth of the bay rather than towards the door. The second factor is the environment: exhaust fumes, grinding dust and paint aerosols settle on the coil, so in such a space the filter is checked weekly. In a spray booth a unit of this type is not used at all - that calls for a dedicated supply and extract system with air treatment. For the repair area, though, a 12 kW UV42R is a practical answer: it creates comfort in the working zone instead of trying to cool the whole volume including the doorway.

The outdoor pairing and commissioning on site

For 12 kW cooling and 13.5 kW heating the catalogue has the single-phase UU42WR (item 1817) and the three-phase UU43WR (item 1821). On an industrial site the choice is usually obvious - three-phase, because the supply is already there and an evenly loaded incomer makes the electrician's life easier. Three things are checked before start-up, being the commonest causes of a failure in the first week: the actual pipe length and the matching top-up charge, the quality of the evacuation, and the tightness of the power connections in the terminal box. That last one is underrated, yet a poor contact on one phase produces heat, a protection trip and a fault that is then hunted for on the circuit board. A commissioning record with pressures, currents and temperatures written down costs nothing and saves hours of diagnosis over a year.

Fan mode: the function nobody uses

Almost every unit has a mode in which only the fan runs, with no cooling or heating, and in spaces like these it is more useful than it sounds. In summer, when a workshop is cool in the morning, ventilation mixes the air and evens out the temperature with no compressor running. In winter the same mode brings back down the heat that has gathered under the roof from heating or from machinery - in a tall space that is several degrees in the working zone. A third use is drying the coil after a spell of cooling: a few minutes of fan-only removes the moisture that biofilm, and then smell, grows from. If the controller allows it, these modes go into a schedule and then run themselves without anyone remembering.

What really determines service life

The compressor of an inverter pair is built for years of continuous running, but what kills it is not hours - it is conditions: unstable voltage, a dirty coil and a shortage of refrigerant after a slow leak. On a supply that dips, the unit's protection trips, the compressor stops and restarts, and every such cycle is a load; where the power is poor we recommend a stabiliser or at the very least good surge protection. A dirty coil forces the system to work at higher pressure and temperature, which cuts its life directly and costs less to prevent than any repair. A slow leak through a weak flare does not announce itself: first the unit simply cools less well, and months later the compressor is running with insufficient cooling of its windings. An annual pressure check and leak test is the cheapest insurance available for equipment of this kind.

Describe the space and list the equipment that generates heat in it, and we will calculate the real load and say how many units of what capacity it needs. We will match the pair, choose mounting positions allowing for doors and columns, and set out a service schedule for your conditions.

Characteristics LG UV42R

Installation type
Стельовий
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Напівпромисловий
BTU
41
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
690 мм.
Indoor unit length
235 mm.
Indoor unit width
1600 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
12000 Вт.
Thermal efficiency
13500 Вт.
Find similar

Reviews about LG UV42R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку