LG UV24R (24,000 BTU, 7 kW) - ceiling-suspended indoor unit with runs up to 30 m
Description LG UV24R
The UV24R: a 7 kW ceiling-suspended unit
The UV24R is a ceiling-suspended indoor unit from LG's R32 semi-industrial range, rated at 7 kW cooling and 8 kW heating. The casing is 1200 mm wide, 690 mm deep and 235 mm high, the supply is 220-240 V, 50 Hz, the refrigerant is R32 and the pair works with a Dual Inverter compressor. Unlike its neighbours in the series, this model's card carries the full pipework data: 1/4 inch liquid, 5/8 inch gas, a 30 metre maximum run and 15 metres of height difference. Manufacturer country and country of origin are Korea, the warranty is 24 months and the casing is metal with plastic parts. No decorative panel is needed: the unit mounts in the open below the slab and comes with a finished casing.
30 metres of pipe: unit in the room, machine on the roof
A permitted 30 metres of pipe and 15 metres of lift give freedom the compact models do not have: the outdoor unit can stand on the roof of a two-storey building or in a courtyard a hundred paces from the room. For premises in a city centre that is often the only option, with a listed facade, windows onto the street and a roof as the only available space. The price of a long run is precision in the installation: oil traps on vertical sections, additional charge calculated from the actual length, and thorough evacuation. A useful rule is to design the run at about two thirds of the permitted maximum, which leaves the margin for going around obstacles that building sites always need. We work out the real length from the drawing before the order, because it governs both the refrigerant volume and the capacity the pair will finally deliver.
Seven kilowatts in an elongated hall
The horizontal stream of a ceiling-suspended unit makes it the natural choice for a room longer than it is wide: the air travels under the ceiling along the space and settles at the far end. For 7 kW that is a hall of roughly 60-75 m², and it works best in a shape close to a rectangle of, say, six by twelve metres. The unit hangs on the end wall or halfway along the long wall, with the flow directed down the length, so that the whole floor gets air with no dead zones. In a room close to square the same capacity distributes better from a CT24R cassette (item 1837), and where the hall splits into zones with different loads, from a CM24R ducted unit (item 1829) with several grilles. The choice of unit type matters more here than the choice of capacity: the same 7 kW in different geometry produces entirely different comfort.
Cafes and restaurants: where to hang it and where never to
In a food business a ceiling unit is convenient because it takes no wall space from furniture and needs no suspended ceiling in a room with exposed services. It is hung above an aisle or along a free wall so the stream travels over the tables rather than onto the necks of the guests at the end table. The one zone to avoid absolutely is above an open kitchen, a grill or a hot display: grease vapour settles on the fan wheel and the coil, and within a season the unit loses capacity while the smell in the room becomes noticeable. Where the layout will not allow distance from the kitchen, you either specify a unit built for frequent cleaning access or move the kitchen's cooling onto a separate system with grease filtration. We have seen enough rooms with a cassette hung over a charcoal grill to recommend this firmly.
A street door: air conditioner or air curtain
In a shop or cafe whose door opens hundreds of times a day, part of the cooling simply leaves, and that load often exceeds everything else combined. The temptation to solve it with a bigger air conditioner is understandable and wrong: the unit will run at its limit and the area by the entrance will still be uncomfortable. The right answer is to split the task: an air curtain cuts off the outdoor air in the doorway while the air conditioner works on a room that no longer has a constant inflow. With a curtain in place, a 7 kW UV24R covers the same hall that without one would need 10 kW and still have a draught at the threshold. We allow for this in sizing and say honestly when the money is better spent on a curtain than on a larger air conditioner.
How it differs from a cassette and a ducted unit
Three unit types at the same 7 kW - the CT24R cassette, the CM24R ducted unit and this UV24R - differ not in capacity but in how they deliver air and what they demand of the room. A cassette needs a suspended ceiling and gives four short streams from the centre: ideal for a square room with an even load. A ducted unit hides completely, but calls for ducts, space for them and a designed network with a static pressure calculation. The ceiling-suspended unit needs neither ceiling nor ducts - it simply hangs under the slab and throws a long stream, paying for that with a casing in view. For rented premises there is a further advantage: the installation barely touches the structure, and at the end of a lease the unit comes down in an hour.
Servicing a unit that is out in the open
The filter withdraws from below or from the side with no ceiling to dismantle - an advantage owners appreciate in the second year of ownership. Wash it monthly in a room with customers and more often in premises with a kitchen, and once a year the coil is pressure-washed with the cover removed. Because the casing is on show, routine cleaning of the outside surfaces joins the list: the white plastic by the intake grille darkens faster than the rest, and that mark is the clearest sign nobody has touched the unit for a while. The drain line is checked too: in a gravity system the trap dries out over a season of inactivity, so it is refilled with water before the summer start-up. All told it is an hour of work once a year plus a few minutes each month, and that is enough to keep the unit at its rated output for its whole service life.
Send the room dimensions, the position of the doors and a photo of the ceiling, and we will place the UV24R so that the stream works on the room rather than into a wall. We will quote the pair with its outdoor unit and, if useful, compare it with the cassette and ducted options.
Characteristics LG UV24R
Reviews about LG UV24R from real users
No reviews found