Catalogue

LG UUD1.U30 (9.5 kW) - outdoor unit for server rooms, 1380 mm casing

CL-000925
135 14800 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG UUD1.U30

The UUD1.U30: a 9.5 kW outdoor unit for server rooms

The UUD1.U30 is the outdoor unit of an LG pair for server rooms and technical spaces, rated at 9.5 kW cooling and 10.8 kW heating. The casing is 950 mm wide, 1380 mm high and 330 mm deep, the supply is single-phase 220-240 V, 50 Hz, the refrigerant is R32 and the compressor is a Dual Inverter. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. The indoor half of this pair is the US36F (item 1850) at the same capacity. The 1380 mm height is the main difference from the smaller UUC1.U40 (item 1849), and it bears directly on where the unit can be installed.

A 1380 mm casing: weight, wind loading, fixings

A tall narrow casing with a two-level coil means not only more capacity but more surface for the wind. On a facade such a unit is fixed with reinforced brackets anchored into the structural wall, and the number of fixing points comes from the manual rather than from habit. In a building with cladding or external insulation the brackets pass through the insulation to the wall with spacers - fixing into the insulation itself holds nothing. On the ground or on a roof the unit stands on a frame with resilient mounts, raised above the surface, and the frame is secured so it cannot walk under its own vibration. The height of that raise allows for snow: for equipment that works through the winter this is not a theoretical consideration but a condition of normal operation.

Single-phase 9.5 kW: what it means electrically

An outdoor unit of 9.5 kW cooling in single-phase form draws a current that can no longer be ignored when designing the board. It gets a dedicated circuit with a breaker and a cable sized by calculation, taking the distance from the board into account - on a long run the cross-section is increased, or the voltage at the terminals dips below limits during starting. If the building already has a three-phase supply, this machine's load is put on the least loaded phase to even out the balance. For a server room it is also settled where the unit is fed from during an outage: it has to come back up with the servers from the generator, or the equipment will run after a power cut while the cooling does not. All of this is fixed in the board schematic before installation, because changing it later means shutting the room down.

Winter: cycles, melt water and ice under the unit

An outdoor unit that cools all year behaves differently in winter from an ordinary split. Its coil runs cold, so frost forms on it, and the defrost cycles produce melt water that has to go somewhere. If the unit stands on the ground with no raise and no drainage, that water freezes and the ice gradually builds until it reaches the bottom of the casing - after which come protection trips and damage. The remedy is simple: raise it on a frame, keep the ground below clear and avoid hollows where ice can collect. In regions with hard frosts a base heater is sometimes considered, but whether that option applies to a particular model is checked in the data sheet rather than assumed.

Where to put it, and where not to

The best position is open to the air, with free access on all sides and shade at midday: direct sun does the coil no harm, but in a heatwave it adds a few degrees to the condensing temperature. The bad positions are equally well known: an unventilated pit, a narrow slot between two walls, a recess behind decorative grilles with little free area, or a platform right beside a kitchen or process extract. In all of them hot air returns to the condenser and capacity falls away exactly when it is most needed. For a server room there is one more criterion - year-round service access: a unit that needs a ladder carried across a lawn in summer becomes unreachable in winter. The position is agreed before installation and recorded with photographs in the design file, so that nobody later discovers the unit was put in a pit temporarily.

Night-time noise and the neighbours

Server room equipment runs around the clock, and at night, when background noise falls away, the outdoor fan becomes audible. If there is an office, a hotel or housing nearby, the discharge direction and the distance to windows are planned in advance: sound travels mainly towards the fan, so turning the unit through ninety degrees sometimes settles the matter entirely. Resilient mounts under the frame and a flexible section in the pipe run deal with the low-frequency hum that travels through the structure and irritates most. An acoustic screen works only if it does not block the airflow: a solid panel in front of the unit reduces noise and kills capacity at the same time. In disputed cases the cheapest solution is a noise measurement on site after installation, which settles the argument with facts rather than assumptions.

Warranty, paperwork and the service rhythm

The 24-month warranty on equipment of this class applies provided it was installed and commissioned to the manufacturer's requirements, which matters especially for a server room, where the machine never pauses. The client should keep the commissioning record with its parameters, the pressure test and evacuation records, the top-up charge calculated from the actual pipe length, and the warranty card. Planned service runs twice a year, with coil washing, pressure checks, drainage and the tightening of connections; the indoor filters are checked monthly. A log with dates and readings shows the trend: if the pressure drifts slightly from visit to visit, that is the signature of a leak which can still be found before the compressor is left without cooling. For a room where equipment stopping means business stopping, that schedule costs less than a single day of downtime.

Tell us what the server room holds and where the outdoor unit could stand, and we will check whether 9.5 kW is enough and advise on a position allowing for winter, noise and access. We will match the pair, work out the electrical side and propose redundancy if the room calls for it.

Characteristics LG UUD1.U30

Installation type
Wall
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Для серверних приміщень
BTU
32
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
1380 мм.
Indoor unit length
330 мм.
Indoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
9500 Вт.
Thermal efficiency
10800 Вт.
Find similar

Reviews about LG UUD1.U30 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку