LG UU60WR (60,000 BTU, 15 kW) - single-phase outdoor unit of a semi-industrial R32 system
Description LG UU60WR
The UU60WR: the top of the single-phase range
The UU60WR is the most powerful single-phase outdoor unit of LG's R32 semi-industrial series: 15 kW of cooling and 16.9 kW of heating in the circuit. The casing is 950 by 1380 by 330 mm, the same as on the 10, 12 and 13.5 kW models, so the dimensions no longer grow - only the load on the compressor and on the supply line does. The supply is single-phase, 220-240 V, 50 Hz; the compressor is a Dual Inverter, the refrigerant R32, production per the card is Korea and the warranty 24 months. The weight is absent from the card; units of this class weigh around 100-110 kg, and the exact figure is taken from the data sheet before designing the base. In output terms this is the level of a small industrial plant, packaged in a form that can still be connected to a single phase.
16.9 kW of heat: what it means for heating
A heating output of 16.9 kW is more than most electric boilers installed in spaces of this size, and the key difference lies in the conversion ratio. An air conditioner does not generate heat but moves it in from outdoors, so for every kilowatt of electricity consumed it delivers roughly three to four kilowatts into the space at moderate outdoor temperatures. For a shop or workshop of 130-160 m² that means a real chance not to run electric heating through the whole of spring and autumn. But there are limits worth knowing in advance: the heating envelope of LG's residential and semi-industrial R32 systems is about -10 °C, and the lower the temperature, the lower the real output. In frost the unit also enters defrost cycles regularly, during which heating pauses for a few minutes, so a system like this is not planned as the sole heat source for winter.
Indoor units at 15 kW, and why one unit is rarely the best answer
Three indoor units suit this outdoor unit: the UM60R ducted unit (item 1833) of 1250 by 360 mm, the UT60R cassette (item 1841) of 840 by 840 mm and 288 mm in height, and the UV60R ceiling-suspended unit (item 1847) 1600 mm long. The problem with 15 kW in a single indoor unit is not the capacity but the air: such a unit has to move a very large volume, and the resulting stream is fast and noticeable. In a room full of people that reads as a draught, so for spaces of 130-170 m² a ducted scheme with six to eight grilles is more often designed, distributing the same air volume without sharp streams. A 15 kW cassette makes sense only in a space with a high ceiling, where the stream decays before it reaches people. A suspended unit saves the day in a workshop or warehouse: it throws a long stream along the space and needs neither a ceiling nor ductwork.
15 kW on one phase: a borderline configuration
In cooling the circuit draws roughly 4.7-5.3 kW and in heating up to 5.5 kW, so the current on one phase is 23-26 A. That requires a dedicated 10 mm² copper circuit, a calculated breaker and an authorised service capacity with real headroom, because this one machine consumes 5-6 kW of the allowance. Let us be open about it: for most sites of this size the sounder solution is the three-phase UU61WR (item 1823) of the same output - about 9-10 A per phase, thinner cable, lower line losses and less phase imbalance in the building. The single-phase version is justified in one case: there are no three phases on site, bringing them in is difficult or expensive, and the single-phase limit can be raised. Before ordering it is worth checking the actual mains voltage under load: with a sag to 195-200 V the inverter board will stop the system and report a supply fault.
One large circuit and the question of reliability
When all the cooling capacity of a site sits in one machine, its failure means the space stops working: in a heatwave a sales floor without cooling loses customers within hours, and production loses output. That is why commercial sites are often designed with two circuits of 7-8 kW rather than one of 15: dearer to install, but if one fails the hall keeps working. The second argument for two circuits is part load: on cool days one machine runs, and the system is not forced to sit permanently at minimum speed. If one large circuit is chosen anyway, it makes sense to sign a maintenance contract with annual cleaning and a pressure check, and to keep the contact of a service that attends within a day in season. For critical spaces - server rooms, laboratories, warehouses with sensitive goods - a single circuit is not designed at all.
Installing a large unit, and the pipework
The base has to carry around 110 kg plus the wind load on a vertical plane of 950 by 1380 mm, which acts as a sail: the frame is fixed to the concrete rather than merely standing on it. At least 2 metres is left in front of the fans, 50-100 cm above the unit and 70 cm on the service panel side: without that gap any diagnosis starts with dismantling. Pipe diameters and maximum lengths for 15 kW come from LG's combination table: they differ by indoor unit, and for a circuit like this the gas line is usually 5/8 inch or larger. The refrigerant top-up on a long run is measured in kilograms, so the rate per metre and the actual length are recorded in the handover documents without fail. Vibration isolation here is no cosmetic matter: a 15 kW compressor produces low-frequency vibration that travels through a steel frame into the building structure and is audible in nearby rooms.
Which jobs it fits and where it is out of place
The UU60WR makes sense in a workshop, a warehouse, a gym, a large shop, a canteen or a hall of 130-170 m², where only one phase is available and the capacity limit allows 5-6 kW for air conditioning. It also suits smaller spaces with large heat gains - a bakery, a print shop, a server room with several racks. Where the model is out of place: a site with three phases, where the three-phase version is technically better in everything but the cost of the supply line; a building with a limited single-phase service; a space that needs continuity of operation. For halls with several zones and differing temperatures one circuit is unsuitable in principle: separate systems or a multi-split system are needed. And if cooling has to work at sub-zero outdoor temperatures, a low-ambient kit is required and its compatibility is checked separately.
How it differs from neighbouring models in this catalogue
The UU48WR (item 1818) offers 13.5 kW in the same casing: lower current, the same installation. The UU61WR (item 1823) is the three-phase equivalent at the same 15 kW: the main alternative to this model. The UU37WR, UU43WR and UU49WR (items 1820-1822) are three-phase units of 10, 12 and 13.5 kW for sites with three phases. The UM60R (item 1833), UT60R (item 1841) and UV60R (item 1847) are the 15 kW indoor units: ducted, cassette and ceiling-suspended. If several rooms need independent control, the alternative is a multi-split system such as the FM57AH (item 1865) at 15.5 kW, which distributes capacity among several indoor units, each with its own controller.
Tell us your authorised capacity and whether three phases are available - we will work out whether a single-phase 15 kW machine will pass and compare it with the three-phase version and a two-circuit scheme.
Characteristics LG UU60WR
Reviews about LG UU60WR from real users
No reviews found




