LG UU49WR (48,000 BTU, 13.5 kW) - three-phase outdoor unit of a semi-industrial R32 system
Description LG UU49WR
The UU49WR: three-phase 13.5 kW
The UU49WR is the outdoor unit of an LG R32 semi-industrial system rated at 13.5 kW cooling and 15.5 kW heating, with a three-phase supply. The casing measures 950 by 1380 by 330 mm, with two fans and forward discharge; the compressor is a Dual Inverter and the refrigerant R32. Per the card, the manufacturer country and country of origin are Korea, the warranty is 24 months and the number of phases three. The weight is not stated on the card; for units of this size one works to 95-110 kg and confirms the figure in the data sheet before choosing the base. The running current per phase is roughly 8-9 A, so the whole output passes along an ordinary five-conductor cable with no special measures.
Power quality on an industrial site
In an industrial zone, in manufacturing and in older retail buildings the network is rarely ideal: voltage sags when large machinery starts, and the board carries harmonics from variable-speed drives and welding sets. Inverter equipment is more sensitive to this than old fixed-speed systems because it has electronics at its input, and the classic symptom of poor supply is intermittent faults and unprompted restarts for no visible reason. Before installation it is worth measuring phase voltages under load at peak hours: if they fall outside 340-440 V between phases, a stabiliser is fitted or the cause of the sag is addressed. If the site has a generator for outages, its rating is calculated with the air conditioner's starting currents in mind, and in many cases it is simpler to exclude air conditioning from the standby supply than to upsize the generator. Running an inverter from a cheap modified-sine UPS is not acceptable: the board reads that waveform as a fault.
Indoor units at 13.5 kW
The units intended for this circuit are the UM48R ducted unit (item 1832) of 1250 by 360 mm, the UT48R cassette (item 1840) of 840 by 840 mm and 288 mm in height, and the UV48R ceiling-suspended unit (item 1846) 1600 mm long. The 13.5 kW ducted unit is noticeably taller than the smaller models - 360 mm rather than 270 mm - and that is the main constraint under a low ceiling: with insulation and drainage some 450-500 mm of service space is needed. The cassette of the same class fits into a suspended ceiling and distributes air four ways; in a space under 3 metres high its stream is felt more than with the smaller models, so the louvre positions are tuned to the layout of the hall. A suspended unit needs neither a ceiling nor ductwork and gives a long directed stream - in a workshop or a gym that is often the only realistic solution. We always verify the pairing against LG's compatibility table.
Control and supervision
Semi-industrial units work with wired controllers: the PREMTB001 (item 1897) and PREMTBB01 (item 1898) are the basic wall controllers with a display, while the PREMTB101 (item 1899) and PREMTBB11 (item 1900) are versions with extended functions. For a site with several systems there is central control: the AC EZ PQCSZ250S0 (item 1905) serves a group of indoor units from one panel, the AC EZ Touch PACEZA000 (item 1906) adds a touch screen, and the AC Smart 5 PACS5A000 (item 1907) is a full controller with schedules, zones and operation logging. For integration into a building management system a PI485 PMNFP14A1 gateway (item 1904) is fitted, which exposes the data over Modbus. The practical benefit of central control for a shop or office is simple: schedules instead of manual switching, limits on the setpoint range so that staff cannot dial in 16 degrees, and a log that shows who changed the mode and when. The PWLSSB21H wireless receiver (item 1901) is added where it is more convenient to control from a handset than from the wall.
Service and the life of the system
Semi-industrial equipment is designed for long operating hours, and its life is determined not by the badge but by the regularity of maintenance. The core task is cleaning the outdoor coil: a radiator clogged with dust and fluff raises discharge pressure, the compressor works overloaded, and consumption rises by 15-25 per cent at the same output. Indoors the filters and the drain tray are cleaned; in a ducted scheme the condition of the ducts and grilles is also checked, because that is where the dirt collects before it spreads through the space. Once a year the readings are taken: circuit pressures, superheat and subcooling, phase currents, air temperatures in and out - this reveals refrigerant loss or fouling before the system stops cooling. The records are best kept in a logbook: in a warranty claim, documented maintenance settles the question faster than any argument.
Installation and pipe routing
The base is calculated for a weight of around 100-110 kg plus wind load; the frame is fixed with anchors rather than left free-standing. The clearances: 1.5-2 metres of clear front ahead of the fans, 50 cm above, 60-70 cm on the service panel side; where two units stand side by side the spacing follows the manual, otherwise each runs on the other's discharge air. Pipe diameters and the maximum run come from the combination table for the specific pair: at 13.5 kW the gas line is usually 5/8 inch, but the value depends on the indoor unit. The pipework is evacuated for at least 40-60 minutes with a vacuum gauge and a hold test: on a circuit like this residual moisture destroys the compressor oil faster than on a domestic system. The condensate drain from the indoor unit is run with a constant fall, and where a fall is impossible an ABDPG drain pump (item 1914) is fitted.
Which jobs it fits and where it is out of place
The UU49WR is taken for a space of roughly 120-150 m² on a site with three phases: a shop, a service hall, a sports club, a production area, a large canteen, an open-plan office. It also suits a smaller space with large heat gains - a kitchen, a laundry, a server room, a workshop with machine tools. Where the model is out of place: a site without a three-phase service - that needs the single-phase UU48WR (item 1818); spaces with several zones at different temperatures; sites that require uninterrupted operation, where two independent circuits are designed. For a warehouse or workshop with doors standing open, comfort cooling does not work - zone solutions are calculated there instead. And if the ceiling in the hall is lower than 2.8 metres, the 360 mm tall UM48R ducted unit may simply not fit, in which case a cassette or a suspended unit is chosen.
How it differs from neighbouring models in this catalogue
The UU43WR (item 1821) is three-phase 12 kW in the same casing: one step down in capacity. The UU61WR (item 1823) is three-phase 15 kW, the top of the series. The UU48WR (item 1818) is the single-phase equivalent of this same 13.5 kW for sites without three phases. The UU37WR (item 1820) is three-phase 10 kW in the more compact 1170 mm casing. The UM48R (item 1832), UT48R (item 1840) and UV48R (item 1846) are the 13.5 kW indoor units: ducted, cassette and ceiling-suspended. If several rooms each need their own temperature, the catalogue offers multi-split systems such as the FM56AH (item 1862) at 15.5 kW, where several indoor units with separate controllers work from one outdoor unit.
Describe the space and the supply on site, and we will check the power quality, select an indoor unit for the UU49WR and tell you whether central control is worth adding.
Characteristics LG UU49WR
Reviews about LG UU49WR from real users
No reviews found