Catalogue

LG UU48WR (48,000 BTU, 13.5 kW) - single-phase outdoor unit of a semi-industrial R32 system

CL-000892
183 96400 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG UU48WR

The UU48WR: 13.5 kW of cooling from one phase

The UU48WR is the outdoor unit of an LG R32 semi-industrial system with a circuit output of 13.5 kW cooling and 15.5 kW heating. The configuration is unusual: capacity like this is normally three-phase, yet here the supply remains single-phase - 220-240 V, 50 Hz, one phase. The casing is the same as on the UU36WR and UU42WR: 950 by 1380 by 330 mm, a tall unit with two fans, so the frame and the location do not change across those three. The compressor is a Dual Inverter, the refrigerant R32; per the card the manufacturer country and country of origin are Korea and the warranty 24 months. The weight is not stated; units of this size weigh roughly 95-105 kg, and the final figure is taken from the data sheet before designing the base.

A current of 22-25 A: when a supply upgrade is needed

In cooling a 13.5 kW circuit draws roughly 4.2-4.7 kW and in heating up to 5 kW, so the current on one phase is 20-23 A and can peak at 25 A. That calls for a 6-10 mm² copper circuit, a breaker of matching rating and, above all, sufficient authorised service capacity: in premises limited to 10 kW this machine cannot be connected at all. If the authorised capacity is short, the question becomes raising the limit under the supplier's technical conditions, and that is a separate procedure with its own timescales and approvals. At this capacity it is worth comparing honestly with the three-phase UU49WR (item 1822): the same cooling, but roughly 8-9 A per phase and a far simpler circuit. The single-phase solution stays justified only where there are no three phases on site and bringing them in costs more than raising the single-phase limit.

Indoor units at 13.5 kW

The UM48R (item 1832) is a ducted unit 1250 mm wide and now 360 mm tall: that matters, because it needs more space above the ceiling than the smaller ducted models. The UT48R (item 1840) is a cassette of 840 by 840 mm and 288 mm in height with four-way distribution. The UV48R (item 1846) is a ceiling-suspended unit 1600 mm long for spaces with an exposed ceiling. At this capacity it is often better to split the hall into two 7 kW circuits than to cover it with one: the evenness of air distribution from a single unit over 130-150 m² is almost always worse. If one circuit it must be, a ducted scheme with five or six grilles gives the best result, while a cassette suits only a compact square space with a high ceiling.

Where 13.5 kW is genuinely needed

Systems like this go into spaces of 120-150 m² with moderate gains, or into smaller spaces with serious equipment: a production area with machines, a bakery with ovens, a server room, a hall with south-facing panoramic glazing. The second typical case is a space with a high ceiling of 3.5-4.5 m, where the air volume far exceeds what the floor area suggests: here capacity is calculated by volume, and 13.5 kW may serve only 90-110 m² of floor. In such spaces stratification becomes critical: warm air collects under the ceiling, and without forced mixing in heating it will be 4-6 degrees cooler at head height. That is why high halls more often get suspended units with a long throw, or a ducted scheme with downward supply. If the space works year-round and needs cooling even at sub-zero outdoor temperatures, a low-ambient kit has to be discussed - the card does not provide for one.

Installation and winter operation

The location is chosen for a weight of around 100 kg, a clear front of 1.5-2 metres ahead of the fans and service access of at least 60-70 cm on the panel side. On the ground it stands on a concrete base or steel frame raised 40-50 cm; on a roof it needs vibration-isolated mounts and a check of the load on the structure. In heating mode the unit defrosts periodically and sheds water, so the drainage is planned so that water does not build ice on a walkway. If the space needs cooling in cold weather - a server room, production with heat output - a standard unit will not work correctly at low outdoor temperatures: fan speed control and crankcase heating are required, that is a separate low-ambient kit whose compatibility we check against the data sheet. Pipe insulation, ultraviolet protection and inspection points on the run are standard conditions, but on a large circuit the cost of getting them wrong is higher.

Commissioning a large system

Commissioning a circuit like this is not a matter of switching it on: before charging comes evacuation and a nitrogen test, and after charging the pressures and temperatures are recorded in every mode. The actual refrigerant top-up for the run length is written into the documents: without that figure the next service works blind. Heating mode is tested without fail even if the system is installed in summer, because that is where errors in the drain and the reversing valve show up. Staff are shown where the filters are, how to remove them and when to rinse them - in a commercial space most of the system's future output depends on that. A commissioning record with parameters and signatures is the basis for any warranty claim: without it, any complaint turns into an argument about installation quality.

Which jobs it fits and where it is out of place

The UU48WR is taken for a production area, a bakery, a gym, a shop, a cafe or an office of 120-150 m², and also for smaller spaces with large heat gains, where only one phase with an adequate limit is available. It is also chosen in refurbishment, where there is no three-phase line and capacity has to be raised within an existing single-phase service with an increased limit. Where the model is out of place: any site with an authorised single-phase capacity of 10-12 kW or less; premises that do have three phases - there the three-phase version is the sounder choice; sites needing continuity and two independent circuits. For a space with several zones one circuit is insufficient in principle. And if cooling is needed in winter, the solution requires a low-ambient kit or specialised equipment such as the US36F (item 1850).

How it differs from neighbouring models in this catalogue

The UU42WR (item 1817) offers 12 kW in the same casing: less current, the same installation. The UU60WR (item 1819) offers 15 kW, the top of the single-phase range, with higher current per phase again. The UU49WR (item 1822) is the three-phase equivalent at the same 13.5 kW: the better choice where three phases are available. The UM48R (item 1832) is the ducted indoor unit 360 mm tall, the UT48R (item 1840) the 840 by 840 mm cassette, the UV48R (item 1846) the 1600 mm suspended unit. If the task is to serve several separate rooms with their own temperatures, a multi-split system is considered instead of one circuit - the FM56AH (item 1862) at 15.5 kW, which distributes capacity among several indoor units.

Tell us your authorised service capacity, the floor area and the ceiling height, and we will check whether single-phase 13.5 kW can be connected and compare it with the three-phase version.

Characteristics LG UU48WR

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Напівпромисловий
BTU
46
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Outdoor unit height
1380 мм.
Outdoor unit length
330 мм.
Outdoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
13500 Вт.
Thermal efficiency
15500 Вт.
Find similar

Reviews about LG UU48WR from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку