LG UU36WR (36,000 BTU, 10 kW) - single-phase outdoor unit of a semi-industrial R32 system
Description LG UU36WR
The UU36WR: 10 kW in single-phase form
The UU36WR is the outdoor unit of an LG R32 semi-industrial system with a circuit output of 10 kW cooling and 10.8 kW heating. The casing here is fundamentally different: 950 by 1380 by 330 mm, a tall vertical unit with two fans rather than the compact box of the smaller models. Despite the capacity the supply remains single-phase - 220-240 V, 50 Hz, one phase - and that is this model's defining feature within the series. The compressor is a Dual Inverter, the refrigerant R32, and the manufacturer country and country of origin on the card are both Korea. The weight is not stated on the card; units of this size typically weigh 85-95 kg, and the final figure is taken from the data sheet before choosing the location and the frame.
10 kW on one phase: what that means for the electrics
A 10 kW circuit draws roughly 3.1-3.5 kW in cooling and up to 3.5-3.8 kW in heating, so the current reaches 15-17 A on a single phase. That is the level at which the circuit is run in 4-6 mm² copper with a calculated breaker, and the building's service is checked separately: in premises with a single-phase limit of 8-10 kW this machine takes most of the permitted capacity. The advantages of a single-phase solution are real too: it can go where there are no three phases at all - an extension, a small workshop, a shop in a residential building. If three phases are available, it is worth comparing with the UU37WR (item 1820) of the same output: the three-phase version spreads the current across phases and loads the supply less. A surge protection relay and a check for voltage sag under load are mandatory: at this capacity the inverter board costs more than any preventive measure.
Indoor units at 10 kW
For this outdoor unit the catalogue offers three indoor types. The UM36R (item 1830) is a ducted unit 1250 mm wide and 270 mm tall, the main solution for concealed installation with air distributed to several grilles. The UT36R (item 1838) is a cassette of 840 by 840 mm and 288 mm in height, with four-way distribution from one point in the ceiling. The UV36R (item 1844) is a ceiling-suspended unit 1600 mm long for spaces with no suspended ceiling: a workshop, a warehouse, a gym, a shop with exposed services. The choice between them depends not on capacity but on geometry: a cassette covers a square, a ducted scheme lets air be delivered to specific points, a suspended unit throws a long stream along the space over 12-15 metres. We confirm the final combination against LG's compatibility table, because not every indoor unit pairs with every outdoor one.
A space of 90-110 m²: how many units to trust the hall to
Ten kilowatts of cooling covers a hall of roughly 90-110 m² with a standard ceiling, provided there are no large internal heat gains. The corrections: kitchen equipment, production machines, a server rack or a south-facing glazed facade easily add 2-4 kW, and then the same 10 kW serves only 60-70 m². The second critical question is one circuit or two: a single 10 kW unit is cheaper to install, while two of 5 kW give redundancy and the option of switching half the system off on cool days. For a shop that is often the decisive argument: if the only machine fails in a heatwave, trading stops, whereas with two circuits the hall keeps working at half capacity. If the space has zones with differing requirements, one circuit is insufficient in principle: a ducted scheme holds one temperature for the entire circuit.
Installing a tall unit
A unit 1380 mm tall does not go on a facade: it stands on a concrete base or a steel frame on the ground, on a plant platform or on a roof with the load on the structure calculated. Units like this draw air through the rear and side faces and discharge forwards through two fans, so at least 1.5-2 metres of free space is needed in front, otherwise the stream returns to the inlet. Above the unit 50-100 cm is left: in snowy regions a canopy is added that does not obstruct the discharge, and the base is raised 40-50 cm above snow level. Vibration isolation at this weight is mandatory: rubber or spring mounts under the feet plus a flexible section in the pipework, because a large compressor's vibration travels readily through the building structure. Service access is planned from the start: at least 60-70 cm on the panel side, otherwise cleaning the coil and replacing a board turn into a dismantling job.
Pipework and charging a large circuit
Maximum pipe lengths and diameters for this capacity come from LG's combination table: they depend on which indoor unit is paired and on the actual geometry of the run. The general rule: the longer the run, the more refrigerant has to be added at the rate per metre, and with large volumes that top-up is measured in kilograms rather than grams. Oil traps on vertical sections longer than 5-6 metres are not a recommendation here but a condition of compressor life. Evacuating a system of this volume takes longer, and the leak test is done with pressurised nitrogen before charging - on a large circuit, finding a leak afterwards is expensive. Each pipe is insulated separately, with protection from ultraviolet on outdoor sections and with inspection points where the run is closed in by construction.
Which jobs it fits and where it is out of place
The UU36WR is the choice for a sales floor, a cafe, a production area, a gym, a warehouse or an office of 80-110 m² that has no three-phase supply but needs serious cooling output. It also suits a case where the space is large but there is no room on the facade: the tall unit goes on the ground or the roof and the pipework is brought in from whichever side suits. Where the model is out of place: a site with a weak single-phase service - 15-17 A per phase simply will not be allowed; premises where continuity of operation matters and two independent circuits are needed; zones with differing temperature regimes. If three phases are available on site, the UU37WR (item 1820) is the better choice. And for a space of 150-200 m² one circuit is insufficient: that points to the UU60WR (item 1819) or several systems.
How it differs from neighbouring models in this catalogue
The UU24WR (item 1815) offers 7 kW in a 950 by 834 mm casing: a shorter unit, less current, a simpler installation. The UU42WR (item 1817) offers 12 kW in the same tall 950 by 1380 mm casing and is likewise single-phase: the next step in capacity with no change in dimensions. The UU37WR (item 1820) offers 10 kW in three-phase form in a 950 by 1170 mm casing: the same output at lower current per phase. The UM36R (item 1830), UT36R (item 1838) and UV36R (item 1844) are the 10 kW indoor units: ducted, cassette and ceiling-suspended respectively. If the task calls for several separately controlled rooms, a multi-split system is considered instead of one circuit, for instance the FM40AH (item 1860) at 11.2 kW distributed to several indoor units.
Tell us the floor area, the ceiling type and what supply you have - one phase or three: we will compare the UU36WR with the three-phase version and select an indoor unit to match the geometry.
Characteristics LG UU36WR
Reviews about LG UU36WR from real users
No reviews found