LG UT60R (60,000 BTU, 15 kW) - the largest cassette of the R32 series, 840x840 mm
Description LG UT60R
The UT60R: the largest cassette in the series
The UT60R is the top cassette model in LG's R32 semi-industrial range: 15 kW cooling and 16.9 kW heating. The casing is the one shared by the larger cassettes: 840 by 840 mm on plan, 288 mm deep, metal with plastic parts, 220-240 V, 50 Hz supply, R32 refrigerant and a Dual Inverter in the pair. Manufacturer country and country of origin are Korea, the warranty is 24 months and the PT-MCGW0 panel (item 1916) is bought separately. Pipe diameters and the maximum run come from the data sheet for the combination with a specific outdoor unit - the card does not list them, and we supply them before installation. There is no larger cassette in the line: anything beyond 15 kW is made up of several units or moves to a different system.
Why one 15 kW cassette is not always the answer
A rating of 15 kW says the machine can remove that much heat; it says nothing about whether it will distribute air evenly across a hall of 150-200 m². The throw from a single point in the ceiling is limited by physics, and the larger the area, the more visible the gap between the centre and the perimeter. The practical consequence is that in a large space two units of 7-10 kW almost always give better comfort than one of 15, even though they cost more to install. A single 15 kW cassette earns its place where the room is compact but heavily loaded - a showroom with a glass facade, a hall full of equipment, a production area. We say this plainly, because a client who bought one powerful machine instead of two medium ones usually spends the saving on fans during the first summer.
Where one such cassette does work well
There are settings in which a single UT60R is exactly right: a car showroom with a high ceiling and the unit in the centre, a sports hall with people moving across the whole floor, a production space with heat-producing machinery and no demand for silence. What those share is the absence of fixed workstations under the unit and a tolerance for air movement that an office would call a draught. Where people sit still for hours, the same capacity is better spread over several points. The second case is a small area with large heat gains: a server room with redundancy, a kitchen block, a laundry where 15 kW is needed over 60-80 m². There the cassette runs near its full output, the stream mixes the air thoroughly, and distribution is not a problem because the walls are close.
Air velocity in the occupied zone
Comfort depends not only on temperature but on air speed: once air moves appreciably faster than a quarter of a metre per second, people read it as a draught even at a perfectly reasonable 24 degrees. A 15 kW cassette moves a large volume, so in a room with a low ceiling the stream still carries real speed when it reaches people, and that is where complaints about air blowing on the back of the neck come from. The remedies are simple: set the louvres flat so the stream clings to the ceiling, use a lower fan speed, and move the unit towards the circulation zone. If the layout will not let you move the unit away from people, two smaller cassettes are the wiser buy, since each discharges more slowly for the same total output. In meeting rooms and offices we rarely specify the larger cassettes at all, because quiet is valued there more than kilowatts.
The outdoor unit: noise outside and the neighbours
The pair for the UT60R is the single-phase UU60WR (item 1819) or the three-phase UU61WR (item 1823), measuring 950 by 1380 by 330 mm. A machine that size has a large fan, and at night it is audible - the only question is whose window it sits under. In an urban setting its position is chosen not just for a convenient pipe run but for the direction the noise travels: a blank wall, a roof, an internal service yard, but not the end wall beside a neighbour's window. Simple measures help: resilient mounts under the frame, flexible connections, and a perforated screen that scatters sound without blocking the airflow. A night mode with reduced fan speed is available in the settings too, and is worth enabling from the start on a site that runs around the clock.
The first start in cold weather: what gets forgotten
A large pair is not started cold off the back of the van in frost: the electronics and the compressor need the supply energised in advance, because the crankcase heater has to warm the oil before the first run. Manufacturers state a specific waiting time, and ignoring it is one of the most banal causes of a brand-new system failing on day one. Three other things are checked at the same time: whether the pipework really was evacuated to the required residual pressure, whether the additional charge was calculated from the actual length, and whether moisture entered the system during installation in wet weather. A cold-weather start is scheduled for the warmer part of the day, and a load is created in the room beforehand so that the unit runs in its normal range rather than at the edge. All of this is the installer's work, but the client should know the list in order to ask the right questions before signing off.
Project budget: the items usually left out
The cassette itself is only part of the cost, and a budget should carry the rest from the start. That means the PT-MCGW0 decorative panel (item 1916), a wired PREMTB001 controller (item 1897) or the wireless PWLSSB21H (item 1901), insulated copper pipework, the power cable, brackets or a frame for the outdoor unit and the drainage works. Difficult geometry adds the ABDPG pump (item 1914); integration into building management adds the PI485 PMNFP14A1 gateway (item 1904); a group of units adds a central controller. Commissioning with evacuation and top-up charge is a line of its own, and a high ceiling adds the hire of a lift for the installation day. With every item in one estimate the comparison becomes honest: sometimes two smaller cassettes with a simpler installation work out better than one large one needing a crane and a platform.
Describe the space and how it is used, and we will tell you whether a single 15 kW cassette is justified or the load is better divided. A full estimate with panel, outdoor unit, controls and installation materials comes as one document.