Catalogue

LG UT42R (42,000 BTU, 12 kW) - 840x840 mm cassette indoor unit for halls up to 150 m²

CL-000913
68 25200 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG UT42R

The UT42R: a 12 kW cassette for a large hall

The UT42R is a cassette indoor unit from LG's R32 semi-industrial range, rated at 12 kW cooling and 13.5 kW heating. The body repeats the UT36R: 840 by 840 mm on plan, 288 mm deep, metal with plastic parts, 220-240 V, 50 Hz supply, R32 refrigerant and a Dual Inverter in the pair. Manufacturer country and country of origin are Korea, the warranty is 24 months, and the PT-MCGW0 decorative panel (item 1916) is ordered separately. The card carries no pipe diameters or maximum run: these follow from the combination with a specific outdoor unit, and we pass them on from the data sheet for the pair before installation. In floor area terms this is a hall of roughly 120-150 m² at normal ceiling height with moderate glazing.

Two kilowatts of difference in the same casing

The UT36R and the UT42R are externally identical: the same 840 mm square, the same panel, the same ceiling opening, the same amount of installation work. The difference hides in coil density and fan output, so choosing between them compares equipment cost alone rather than project cost. That simplifies the decision when a calculation lands at an awkward 11 kW: taking the larger model is logical, because the extra applies only to the pair of units, while reworking a system short of capacity would touch everything. The other side is familiar - an oversized machine holds humidity less well and cycles more often - so two or three kilowatts of margin are taken deliberately rather than just in case. We prefer to work from a calculation with real glazing and equipment data instead of the kilowatt-per-ten-square-metres rule, which systematically misleads in retail spaces.

The heat gains people usually miss

Floor area is only one variable, and in a 150 m² hall it often accounts for less of the load than everything else combined. Accent lighting in a shop easily adds several kilowatts of heat, refrigerated display cases dump their condenser heat into the room, and every person moving about contributes around a hundred watts. South or west glazing on a summer day behaves like a heater: a square metre of unshaded window loads the system like several people, which is why two halls of equal area can differ by several kilowatts. Add the outdoor air coming through a door that opens constantly - in a busy shop that is hundreds of cubic metres an hour to be cooled. Once all that is counted, the UT42R often turns out to be the right pick where area alone suggested the 10 kW model would do.

Noise: where to put a cassette in a cafe or waiting room

A 12 kW unit moves more air than the smaller models, so at high fan speed it is audible, and that belongs in the layout. In a restaurant the cassette is not placed directly above the window tables but shifted towards the aisle: the stream runs along the ceiling and descends further away, so guests do not sit in it. In a waiting room or a pharmacy the same principle applies to places where people stay a long time - a chair under a cassette becomes the least popular seat in the room. In an open-plan office the unit is shifted towards the circulation zone and the louvres above the desks are flattened against the ceiling, using the way a stream clings to a surface. Where acoustics really matter - a meeting room, a studio, a consulting room - a ducted layout with attenuators is worth considering, because there the noise is controlled by duct design rather than by fan speed alone.

A three-phase pair and running from a generator

The catalogue offers a single-phase UU42WR (item 1817) and a three-phase UU43WR (item 1821) for the UT42R at the same 12 kW cooling and 13.5 kW heating. At this capacity the three-phase version is the more practical: lower current per phase, an evenly loaded supply and simpler cabling. A separate question, relevant on many sites, is running from a generator during outages. An inverter pair copes with a generator better than older designs with direct compressor starting, because there is no abrupt starting surge, but the generator still has to be sized with a margin and produce a clean sine wave, or the unit's electronics may refuse to start. Before connecting to a generator we suggest checking with the service team: the issue lies with the source and the stability of its voltage when fans and compressor start, not with the air conditioner itself.

Summer heat and winter operation outdoors

For LG's domestic and semi-industrial R32 units the typical cooling range is roughly -10 to +48 degrees and the heating range roughly down to -10; the exact limits for a particular combination are checked against the data sheet for the pair, which we do before the sale. What matters more in practice is how the outdoor unit is installed. One squeezed into a recess with no air supply, or standing in full sun on a south wall, loses capacity in a heatwave and runs at its limit even when the ambient temperature is formally within range. The minimum clearances to walls and neighbouring units are in the manual and are observed for a reason: hot air recirculating back to the condenser is the commonest cause of trips in July. In winter what matters is free drainage of melt water from under the unit and no wind blowing straight into the coil, plus, on a roof, enough height above snow level.

The PT-MCGW0 panel and the usual installation mistakes

The panel for this cassette is about 950 mm a side, so it overlaps the opening - and that overlap occasionally surprises everyone when a line of luminaires or a track runs nearby. The second point is how deep the unit hangs: too high, and a gap opens between panel and ceiling through which dusty air from the void is drawn in, leaving a grey outline around the panel within a year. The third is levelling: the cassette is levelled with a spirit level rather than to the ceiling, because the ceiling may have a slope of its own, and tilt is exactly what makes the tray overflow. The fourth is the wiring: the controller cable and the power line are run to the unit in advance, since pulling them after the ceiling is closed means partly dismantling it. Each of these costs half an hour during installation and a full day afterwards.

Send us the floor plan, the type of glazing and a list of heat-producing equipment, and we will calculate the load honestly rather than by the kilowatt-per-ten-square-metres rule. You will get a UT42R set with its panel and an outdoor unit matched to the supply you have.

Characteristics LG UT42R

Installation type
Касетний
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Напівпромисловий
BTU
41
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
288 мм.
Indoor unit length
840 мм.
Indoor unit width
840 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
12000 Вт.
Thermal efficiency
13500 Вт.
Find similar

Reviews about LG UT42R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку