LG UT36R (36,000 BTU, 10 kW) - 840x840 mm four-way cassette for halls up to 130 m²
Description LG UT36R
The UT36R: a four-way 10 kW cassette
The UT36R is a cassette indoor unit from LG's R32 semi-industrial range, rated at 10 kW cooling and 10.8 kW heating. The body measures 840 by 840 mm on plan and 288 mm deep, runs on 220-240 V, 50 Hz, uses R32, pairs with a Dual Inverter compressor and is built of metal with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. The decorative panel is ordered separately: for the 24-60 kBTU range it is the PT-MCGW0 (item 1916), the same one the CT24R uses. Pipe diameters, maximum run and height difference are not on the card - they depend on the outdoor unit chosen, and we supply them from the combination data sheet before installation so that the crew buys the right copper and insulation first time.
The same 840 mm square, 84 mm deeper
From below the UT36R is indistinguishable from the CT24R - the same square panel in the ceiling - but the body has grown to 288 mm from 204 mm. That follows directly from the output: taking out 10 kW needs a larger coil and a higher airflow, and both need volume. For the design it means a void of roughly 360-380 mm once resilient mounts, drain fall and pipe insulation are counted, which an office suspended ceiling normally has, while a 2.7 metre room does not without making the space feel tight. Check the clearance at the actual mounting point, because beams, ventilation ducts and cable trays run unevenly, and the centre of a room - where a cassette looks best - often turns out to have less room than the edge. Where the depth is not available, the same capacity comes as the UM36R ducted unit (item 1830) or the UV36R ceiling-suspended unit (item 1844).
10 kW from one point in the ceiling: the limits of evenness
A 10 kW cassette covers a hall of 100-130 m² on paper, and this is where a question sellers usually avoid begins: will the air actually reach the edges of that area. The throw from a single point is finite, and in a square hall some ten metres across the perimeter receives noticeably less air than the centre. In practice that is a difference of one or two degrees between the middle and the corners, which nobody notices in a shop and everybody by the window notices in an office. Where the room is elongated, or partitions, columns and tall shelving break it up, one 10 kW cassette loses to two 5 kW units spread across the floor, even allowing for the cost of a second set. We work this out from the plan: when the aspect ratio is worse than one to one and a half, we almost always propose two smaller machines.
Ceilings of 3.5-4 metres: good at cooling, weaker at heating
In a room over three metres high a cassette cools naturally: cold air is heavier, it falls into the occupied zone by itself and the throw is sufficient. In heating the picture reverses - warm air tries to stay aloft, and part of the output goes into warming the space above people's heads. The practical consequences: in winter the louvres go to their lowest position, the fan runs faster, and in a tall, heavily glazed hall the air conditioner is treated as a supplementary rather than the main heat source. For buildings that need real heating, the same catalogue offers the Therma V heat pumps (items 1877-1887), which work with a water circuit, radiators or underfloor heating. Honesty pays here: a client who was told in advance how a cassette behaves in winter does not conclude in January that the equipment is faulty.
The outdoor pairing: single phase or three
Two outdoor units in the catalogue match 10 kW cooling and 10.8 kW heating: the single-phase UU36WR (item 1816) and the three-phase UU37WR (item 1820), the latter measuring 950 by 1170 by 330 mm. At this capacity three-phase supply stops being a formality: a single-phase machine draws a current that visibly dips the voltage on an older incomer, and in a building with other equipment that shows in the lighting. The three-phase version loads the supply evenly, allows a smaller cable cross-section per phase and behaves better in a building with a lift, pumps or kitchen equipment. If the premises are rented and the supply cannot be altered, we calculate the existing balance and say plainly whether the pair fits within the limit or another arrangement is needed. This is settled before ordering, because it affects not only the unit but the cost of the electrical work.
Servicing a cassette at height
A 10 kW unit in a four-metre-high sales area is not serviced from a stepladder but from a platform or a scissor lift, and that belongs in the running budget from the start. The filter withdraws downwards through the panel, but the tray, the condensate pump and the terminal box require the panel to be partly removed, which means two people and access equipment. In a supermarket that work is scheduled for the night or the hour before opening, and the service contract is better written around the site's hours than around breakdowns. The interval between visits depends on dust: in a food hall with an in-store bakery the coil fouls faster than in an office, and an annual wash is not optional. With access thought through, servicing one cassette takes an hour; without it, half a day including dismantling part of the ceiling.
Why supermarkets often choose a cassette over ductwork
In a sales area with a finished ceiling the cassette wins on speed: no ducts, no static pressure calculation, no balancing - a unit, a panel, a pipe run and a controller. For rented premises there is also the question of reversibility: a cassette is unbolted and taken along when the tenant moves, while a duct network stays with the landlord. The ducted unit wins elsewhere - it can feed several zones and hide the equipment completely - but it needs a design, space for the ducts and more installation time. The decision usually comes down to three things: the depth of the ceiling void, the length of the lease and whether the hall has zones with different loads. With a ceiling already in place, a three to five year lease and a uniform hall, the UT36R with a PT-MCGW0 panel is a faster and cheaper answer than any ducted layout.
Send the floor plan with dimensions and ceiling height and we will work out whether one 10 kW cassette will do or the load is better split between two machines. You will get back a set with panel, an outdoor unit matched to your supply, and pipe diameters from the data sheet for the pair.