Description LG MU4R27

The MU4R27: four indoor units and 7.9 kW of cooling

The MU4R27 is the outdoor unit of an LG R32 multi-split system rated at 7.9 kW cooling and 9.1 kW heating for four indoor units. The casing is larger than the smaller model: 950 mm wide, 834 mm high, 330 mm deep; single-phase 220-240 V, 50 Hz, Dual Inverter compressor, metal construction with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. Indoor units come from the multi range - the MA09R and MA12R wall units (items 1866-1867), the MJ05PC to MJ24PC (items 1868-1874), the MT09R and MT11R cassettes (items 1875-1876). Against the MU4R25 (item 1856) this is nearly a kilowatt more capacity, in a noticeably larger and heavier casing.

What 7.9 kW across four units buys you

The extra capacity is not for cooling more rooms but for allowing the rooms to be bigger. An MU4R25 works comfortably with four units of 7,000 to 9,000 BTU; an MU4R27 lets you specify a 12,000 or even 18,000 BTU unit in the living room plus three smaller ones in bedrooms. The difference becomes critical in a house with a large living room open to the kitchen: there one unit has to cover thirty-five to forty-five square metres with substantial glazing. The second situation is an office where all four rooms run simultaneously for eight hours and there is simply nowhere to put the overlap. If all four rooms are small, however, the larger model will work at the bottom of its range, and paying for unnecessary headroom makes no sense.

A 950 by 834 casing: installation of a different order

A tall casing changes the installation requirements: standard domestic brackets will not do, and reinforced ones anchored into the structure with enough fixing points are needed. On the ground the unit stands on a concrete base or a steel frame with resilient mounts, raised above the surface so that water and snow never reach the bottom panel. This unit weighs enough that fitting it to a facade calls for lifting equipment or at least a crew of three - worth bearing in mind when scheduling the work. Minimum clearances to walls and fences are observed per the manual: a tall machine moving a lot of air is especially sensitive to recirculating its own hot air. If the position is tight, it is better to change it than to put the unit in a pocket between walls and then wonder about protection trips in hot weather.

A house with attic rooms: a separate problem

Attic rooms heat up the most: the roof takes the sun all day, and even with good insulation it is hotter under it than on the ground floor. For such rooms an area-based calculation understates the need, so the indoor unit is taken one step larger. The second feature is geometry: sloping ceilings limit the space for a wall unit, and often the only usable wall turns out to be the gable, beside the window. The third is height: an outdoor unit at ground level and an indoor unit in the attic create a vertical difference that must stay within the limit in the model's data sheet. The fourth is drainage: getting condensate out of an attic is harder than from the ground floor, so the route is planned in advance, because a pump in that position adds both noise and another component to maintain.

Quiet operation at night in a private house

In a house the outdoor unit often stands close to bedroom windows, and at night that is audible. The first thing that settles it is position: a unit under a bedroom window is worse than one by the service entrance, even if the pipe run is a little longer. The second is night mode: many indoor units in the multi range reduce fan speed, while the system lowers the outdoor unit's output, and together that is noticeably quieter. The third is mounting: vibration transmitted through the house wall is audible in the next room even with a quiet unit, so resilient mounts and decoupled pipework are essential. The fourth is duty: a correctly sized system holds temperature steadily instead of ramping up every hour, and it is the swings that wake people, not the steady background sound.

Heating four rooms in the shoulder seasons

9.1 kW of heating allows four rooms to be warmed in September and October, March and April, when the main heating is off but the evenings are already cool. For a house that is a practical saving: instead of firing the boiler for the whole circuit you can warm just the rooms in use. The limitations are the usual ones: as the outdoor temperature falls, heating output drops, and in hard frost a multi becomes a supplementary source. The second limitation is the shared mode: all four units work either on cooling or on heating, so in the transitional season you cannot heat the bedroom and cool the study at the same time. If full heating by heat pump is the goal, the right direction is Therma V (items 1877-1887) with a water circuit, leaving the multi for summer cooling.

Can the indoor units be connected in stages

The question comes up often: buy a four-port outdoor unit, fit two indoor units now and two later. Technically it is possible, but with conditions. Unused ports are capped as the manufacturer specifies, and the system is charged for the actual configuration rather than the future one. When a third unit is added a year later, a full visit is needed: running the pipework, pressure testing, evacuating the new line and recalculating the charge - not simply connecting it up. A second nuance is the warranty: all the work has to be done by a qualified crew with documentation, or any claim about the equipment becomes disputable. So staged installation makes sense when the plan is definite and the dates are known; if the fourth room is only an idea, it is wiser to buy for the real requirement.

What is in the box and what is bought separately

An outdoor unit is the unit itself, and that is what to expect: indoor units, pipework, insulation, interconnecting cables, brackets and drainage materials are bought separately for the specific project. The MT09R and MT11R cassettes additionally need a decorative panel, chosen to match the model. If control from a phone is wanted, the PWFMDD202 Wi-Fi module (item 1903) is added, which works on a 2.4 GHz network. PREMTB001 wired controllers (item 1897) go where a handset is awkward or gets lost. We always send a full list marking what is included in the delivery and what the installers supply separately - which removes the most common disappointment when an order arrives.

Describe the four rooms - areas, window orientation, whether any are in the roof - and we will say whether 7.9 kW is really needed and choose the indoor combination. If the installation is to be staged, we will explain how to do it so that the second phase does not undo the first.

Characteristics LG MU4R27

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
27
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
834 мм.
Outdoor unit length
330 мм.
Outdoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
7900 Вт.
Thermal efficiency
9100 Вт.
Find similar

Reviews about LG MU4R27 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку