Catalogue

LG MU3R21 (6.2 kW) - multi-split outdoor unit for 3 indoor units

CL-000929
126 56000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG MU3R21

The MU3R21: a three-room multi with more capacity

The MU3R21 is the outdoor unit of an LG R32 multi-split system rated at 6.2 kW cooling and 7 kW heating for three indoor units. The casing is 870 mm wide, 650 mm high and 330 mm deep, the supply is single-phase 220-240 V, 50 Hz, the compressor is a Dual Inverter and the construction is metal with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. Indoor units come from the multi range: the MA09R and MA12R wall units (items 1866-1867), the MJ05PC to MJ24PC (items 1868-1874) or the MT09R and MT11R cassettes (items 1875-1876). Against the MU3R19 (item 1854) the difference is almost a kilowatt of cooling with the same casing and the same installation.

When three rooms are too much for the smaller model

6.2 kW instead of 5.3 is needed when the rooms are larger than typical or when one of them opens onto a kitchen. The second case is a flat with panoramic windows: modern buildings glazed to half the wall take in so much sun in summer that an area-based calculation understates the need by a third. The third is a house where three upstairs rooms warm up from the roof. There is a fourth, less obvious one: if several computers or professional equipment run constantly in one room, that adds hundreds of watts of heat which standard calculations never include. If the three rooms are ordinary, fifteen to eighteen square metres with east and north windows, the MU3R19 will cope just as well and cost less.

A unit in an open-plan kitchen: a special case

An open-plan kitchen is the hardest room for an air conditioner, and it is often the reason the larger model is chosen. The hob, the oven and the fridge add heat, the extractor removes part of the air, and the open layout means the unit has to serve both the cooking area and the living space. First rule: the indoor unit is not hung above the worktop and its airflow is not aimed at the hob - that disturbs a gas flame and draws grease onto the coil. Second: filters in a kitchen unit clog faster than in a bedroom, so they are washed more often, and every few years a deep clean of the coil is worthwhile. Third: an open-plan kitchen usually takes the largest unit in the system, and it is precisely the room where saving on capacity shows up first.

What actually drives the electricity bill

An inverter multi system consumes what it needs to hold the temperature, so the main factor in the bill is not the nameplate rating but how much heat enters the flat. Closed blinds on the sunny side during the day save more than any setting on the air conditioner. Second in importance is the set point: every degree below what you actually need adds noticeably to consumption, and the gap between 24 and 21 degrees is large on a bill. Third is the operating pattern: holding a comfortable temperature continuously is usually cheaper than switching off all day and then cooling a heat-soaked flat from scratch. Fourth is the condition of the filters and coils: dirty equipment uses more for the same work, and cleaning is the cheapest way to get the efficiency back.

Installing an 870 by 650 unit: where it physically goes

The outdoor unit of this series is noticeably larger and heavier than a domestic one, so the position is checked in advance rather than on the day of installation. A facade needs reinforced brackets anchored into the structure and enough room for access: minimum clearances to walls and neighbouring equipment come from the manual. The commonest mistake in flats is putting the unit on a glazed balcony: in an enclosed space the hot air has nowhere to go, the unit works against itself and on a hot day the system simply trips on protection. If the balcony is glazed, a permanent inlet and outlet to the open air is required, and that arrangement is calculated rather than improvised. On the ground floor there is also protection against damage and curious passers-by - a louvred cover is fitted that does not block the airflow.

Three drain lines in a flat

Each of the three indoor units produces condensate, and in summer that is litres of water a day across the system. The proper solution is to run the drains into the waste system through a trap, which stops odour rising into the room. Discharging onto the facade is acceptable only where the water cannot reach the windows and balconies below: drips on a neighbour's sill are the commonest cause of air conditioning disputes between flats. Where the stack is far away, a condensate pump is sometimes fitted to lift the water to the right point; it works, but a pump is one more component that needs servicing. All three lines are run with a continuous fall and no sags: a loop where water stands turns into a blockage within a season and leaks into the room.

Approvals in an apartment building

Before ordering a multi system in a flat, it is worth learning your building's rules: many management companies have designated positions for outdoor units or require them on the courtyard side only. In buildings whose facade forms part of a listed structure, an unapproved installation can end with an order to remove it, which costs far more than getting agreement first. A multi has an advantage here: one unit can be approved even where three would be refused. Service access is worth thinking through in advance too: if the unit hangs above someone else's balcony, every service visit becomes a negotiation with the neighbours. We can suggest the wording usually needed in an application to the building management, and which positions are most often approved without objection.

Servicing a system with three indoor units

The routine is simple, but its volume multiplies by the number of indoor units: filters in each room are washed monthly during the working season, coils are cleaned once a year, drains are checked before summer. The outdoor unit is serviced once, and for a multi that is a real saving of time against three separate air conditioners. Pressure is checked annually: in a multi with a long total pipe run a slow loss of refrigerant shows up as a gradual fall in performance that is easy to blame on the weather. Keeping a log of visits with readings is useful - it shows the trend, and a leak is found before the compressor starts working in poor conditions. If the system was installed during a refurbishment, keep the pipe route drawing: in a few years, when somebody needs to drill the wall, that drawing will be worth more than any accessory.

Describe the three rooms - area, window orientation, whether one is an open-plan kitchen - and we will calculate the capacity each needs and say whether this model is the right one. We will also suggest a position for the outdoor unit and a drain route, so that water never becomes a conversation with the neighbours in summer.

Characteristics LG MU3R21

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
21
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
650 мм.
Outdoor unit length
330 мм.
Outdoor unit width
870 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
6200 Вт.
Thermal efficiency
7000 Вт.
Find similar

Reviews about LG MU3R21 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку