Catalogue

LG MU3R19 (5.3 kW) - multi-split outdoor unit for 3 indoor units

CL-000928
102 60400 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG MU3R19

The MU3R19: one outdoor unit for three rooms

The MU3R19 is the outdoor unit of an LG R32 multi-split system rated at 5.3 kW cooling and 6.3 kW heating for three indoor units. Its casing is larger than the two-port models: 870 mm wide, 650 mm high, 330 mm deep; single-phase 220-240 V, 50 Hz, Dual Inverter compressor. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. Indoor units come from the multi range: the MA09R and MA12R wall units (items 1866-1867), the MJ05PC to MJ18PC (items 1868-1873), and the MT09R and MT11R cassettes (items 1875-1876). Three indoor units on one outdoor is the standard answer for a three-room flat where only one machine may appear on the facade.

Three rooms: what that looks like in a real flat

The commonest configuration is a living room, a bedroom and a child's room or study, and this model was built for exactly that. The living room usually takes the largest unit, having more floor area, more glazing and more people; the bedrooms take smaller ones, because the night-time load is lower. Three separate splits in such a flat would mean three outdoor units on the facade, three sets of pipework and three places to put machines on the balcony or wall. A multi reduces that to one unit and one electrical connection, which in an apartment block is often the only workable option. The other side deserves a mention: all three rooms depend on one compressor, so planned service or a repair stops the air conditioning in the whole flat at once.

Dividing 5.3 kW between three units

The typical combination for this model is three units of 7,000 to 9,000 BTU, or two nines plus one smaller. The sum of the indoor ratings may exceed the outdoor capacity, and that is normal: three rooms rarely run at maximum simultaneously. But if the family is home all day and all three units run in summer, each gets less than its rating, and on the hottest day that will be noticeable. The practical rule: the greater the overlap in the sum, the more important it is that the rooms are used at different times. The permitted combinations and the maximum overlap ratio for the MU3R19 come from the manufacturer's table, which we check and confirm before the order, because the system may simply not accept an arbitrary set of units.

Units of 5,000 BTU: why so small

The range includes the MJ05PC indoor unit (item 1868) at 5,000 BTU, and buyers often pass it by as too weak. In fact, for a bedroom of nine to twelve square metres with one north window it is exactly right: a larger unit in such a room reaches temperature in a few minutes, stops and then works in bursts. Short cycling means not only temperature swings but poorer dehumidification, because moisture only condenses while the coil runs for a sustained period. In a three-unit system, small models also reduce the total overlap and leave more headroom for the living room. So we always size each room separately rather than fitting three identical units out of habit - it costs less and works noticeably better.

Pipe lengths in a three-line system

With three indoor units the question of pipe length becomes serious: there are limits on each individual line, on the total length of all lines, and on the height difference between the outdoor unit and the furthest indoor one. In a flat laid out horizontally the far room may be twenty metres from the balcony, and together with the other two lines the limit comes close. The second point is the refrigerant charge: beyond the base pipe length the system is topped up by calculation, and that is done at commissioning rather than later when it gets warm. The third is routing: three pairs of pipes in one trunking run look bulky, so the route is planned so the lines separate as early as possible. All these figures come from the model's data sheet, and we provide them before installation so the crew calculates rather than guesses.

Controlling three units

Each indoor unit comes with its own handset, which suits many families, but in a flat with three air conditioners handsets start disappearing. There are two alternatives: a PREMTB001 wired wall controller (item 1897) in each room, which cannot be mislaid and looks like an ordinary thermostat, or the PWFMDD202 Wi-Fi module (item 1903) for control from a phone. One detail matters for Wi-Fi: the module works on a 2.4 GHz network, so that band has to be enabled on the router or the connection simply will not happen. From a phone it is convenient to start the bedroom an hour before bedtime, or to switch everything off with one gesture on the way out. Where children or elderly people live in the flat, a wired controller often proves more practical than an app - its battery never dies and it is always in the same place.

How not to get the capacity wrong

The main mistake when buying a multi system is calculating capacity from the flat's total floor area. Three rooms of fifteen square metres and three of twenty-five are different problems, and two models of the range lie between them. The second mistake is ignoring orientation: a room with a west window takes the sun during the hottest hours and needs more cooling than the same room facing north. The third is forgetting the kitchen: if one unit is planned for an open-plan kitchen, the hob and the fridge add heat, and a plain area calculation understates the need. If after all the sums you find yourself between the MU3R19 and the larger MU3R21 (item 1855), and at least one room has large south-facing glazing, take the larger one - headroom in a multi system is used up faster than it seems.

Send us the area, window orientation and use of all three rooms, and we will calculate the capacity each one needs and verify the combination against the manufacturer's table. We will also suggest where the outdoor unit should go so that the run to the far room stays within the permitted length.

Characteristics LG MU3R19

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
18
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
650 мм.
Outdoor unit length
330 мм.
Outdoor unit width
870 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
5300 Вт.
Thermal efficiency
6300 Вт.
Find similar

Reviews about LG MU3R19 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку