Catalogue

LG MU2R17 (4.7 kW) - multi-split outdoor unit for 2 indoor units

CL-000927
86 78400 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG MU2R17

The MU2R17: a two-room multi with headroom

The MU2R17 is the outdoor unit of an LG R32 multi-split system rated at 4.7 kW cooling and 5.3 kW heating for two indoor units. The casing matches the smaller model: 770 mm wide, 545 mm high, 288 mm deep, single-phase 220-240 V, 50 Hz, with a Dual Inverter compressor. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. Indoor units come from the multi range: the MA09R and MA12R wall units (items 1866-1867), the MJ05PC to MJ18PC (items 1868-1873) or the MT09R and MT11R cassettes (items 1875-1876). The only difference from the MU2R15 (item 1852) is capacity - casing, installation and operating logic are identical.

Six hundred watts of difference: who needs the larger model

4.7 kW instead of 4.1 kW looks like a detail, but in practice that difference decides whether the system holds two rooms through a heatwave. The larger model is chosen when at least one room has a panoramic window facing south or west, when the ceiling is above two metres seventy, or when people and equipment work in the rooms continuously. The second case is a combination of a 12,000 BTU unit in the living room and a nine in the bedroom: for that pair 4.1 kW is already short. The third is a top-floor flat under a hot roof, where summer heat gain is noticeably above typical. If both rooms are small with east or north windows, there is no sense paying for headroom - the smaller model will perform better, because it will work in a range that suits it.

One connection point to the electrical supply

A multi system has a practical advantage that rarely gets mentioned: the outdoor unit connects to the mains, and the indoor units are usually fed from it through the interconnecting cable. That means one circuit from the board instead of two, one group of breakers and no need to run a separate socket into each room. For a finished flat whose board is already assembled this is often the decisive argument - adding one circuit is realistic, two from opposite ends of the flat is far harder. The exact wiring arrangement is checked by the installer against the manual for the specific model, because the details matter and must not be recited from memory. Cable cross-section and breaker rating are calculated for the full system load rather than for one indoor unit - a basic requirement, and a frequently broken one.

A wall unit and a cassette in the same system

An MU2R17 does not have to carry two identical indoor units: a multi system allows different types to be mixed, and that is often the smartest answer. In a living room with a suspended ceiling and a service void you can fit an MT09R cassette (item 1875), which takes no wall space and distributes air in all directions; in the bedroom a conventional wall unit, because nobody wants to lower the ceiling there. The combination solves an old problem: a wall unit in a bedroom is intrusive because it blows into one zone, while a cassette there is usually impossible for lack of ceiling depth. There are limits too: each type has its own installation and drainage requirements, and a cassette needs a panel chosen separately. We verify the specific combination against the manufacturer's table and say in advance what is included and what is bought additionally.

When only one room is running

The commonest duty for a multi system is not both rooms at once but one: the bedroom at night, the study by day. An inverter compressor in that mode drops to a fraction of its rating and runs in long quiet cycles, which is where the economy and the low noise come from. It differs markedly from older fixed-speed systems, which in that scenario switched on and off every few minutes. There is a flip side: if only one small indoor unit of the two runs regularly, the system works at the bottom of its range and the point of a large multi is partly lost. So capacity should be chosen for the real scenario: if the second room is used once a month, an ordinary split in the main room plus a separate unit later may serve better.

Heating in the shoulder seasons: when it pays

5.3 kW of heating allows the system to be the main heat source in the shoulder seasons - September to October and March to April, when district heating is not yet or no longer running. A heat pump in this mode is far more efficient than any electric convector, because it moves heat rather than converting electricity into it directly. The limitation is well known: as the outdoor temperature falls, output drops, and in hard frost a multi system becomes supplementary heating rather than primary. The second limitation was mentioned earlier: both rooms must be in the same mode, so heating one while cooling the other is not possible. For a flat with normal central heating this is more than enough; for a house where the air conditioner is meant to be the main winter heat source, the right direction is the Therma V heat pumps (items 1877-1887).

Planning the pipe runs during a refurbishment

A multi system is easiest to install while the walls are still open: two pairs of copper pipes, two drains and the interconnecting cables go into chases, and nothing remains on the surface except the indoor units. If the work is already finished, the runs have to go in trunking along walls or ceilings, and the appearance often comes as an unwelcome surprise. One more thing is planned early: all the runs converge at the outdoor unit, so its position effectively determines the route of both lines through the flat. Each unit's drain needs a continuous fall to the discharge point, which constrains mounting height and routing. If you are mid-refurbishment, the cheapest step is to call an installer before the plastering: an hour of advice now saves weeks of rework later.

Tell us the area and orientation of both rooms, the ceiling height and the floor, and we will say whether 4.7 kW is enough and choose the indoor combination. If the work is still under way, we will show where to lay the pipe runs so that trunking is never needed on the walls.

Characteristics LG MU2R17

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
16
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
545 мм.
Outdoor unit length
288 мм.
Outdoor unit width
770 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
4700 Вт.
Thermal efficiency
5300 Вт.
Find similar

Reviews about LG MU2R17 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку