Catalogue

LG MU2R15 (4.1 kW) - multi-split outdoor unit for 2 indoor units

CL-000926
79 10000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG MU2R15

The MU2R15: a multi-split outdoor unit for two rooms

The MU2R15 is the outdoor unit of an LG R32 multi-split system, rated at 4.1 kW cooling and 4.7 kW heating and designed for two indoor units. The casing is 770 mm wide, 545 mm high and 288 mm deep, the supply is single-phase 220-240 V, 50 Hz, the compressor is a Dual Inverter and the construction is metal with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. On its own this unit does nothing: it is matched with indoor units from the multi range - the MA09R wall unit (item 1866), the MJ05PC to MJ12PC (items 1868-1871) or the MT09R and MT11R cassettes (items 1875-1876). Indoor units from ordinary single splits will not work on a multi system, and that is the first thing to know before ordering.

A multi system versus two separate air conditioners

Two rooms can be cooled by two ordinary splits or by one multi system with two indoor units, and these really are different solutions rather than variations on one. A multi gives you one outdoor unit instead of two: the facade stays clean, the balcony keeps its space, and in a building with strict rules about outdoor units it is often the only permitted option. The price is a shared fate: when the single compressor stops, both rooms lose cooling, whereas two separate systems are independent. There is an economic side too: a multi usually costs more to buy but less to install where the second outdoor unit would need pipework run across half the house. Our advice is to choose by situation rather than by price: facade restrictions point to a multi, freedom of placement and a need for uninterrupted operation point to two separate machines.

Dividing 4.1 kW between two rooms

An outdoor unit of 4.1 kW is normally fitted with two indoor units of 2 to 2.6 kW - two nines, for instance, or a seven and a nine. One nuance matters: the sum of the indoor ratings may exceed the outdoor capacity, because they rarely run at maximum together. But if both rooms have large south-facing glazing and are used at the same time during the hottest hours, that excess shows up as neither room quite reaching temperature. So the combination is chosen from the real pattern of use rather than from what will fit on paper: a bedroom at night and a study by day peak at different times, and then the overlap is acceptable. The permitted indoor combinations for this model come from the manufacturer's table, which we check and confirm before the order.

One mode for the whole system: the limitation nobody mentions

On multi systems of this class every indoor unit works in the same mode: either cooling or heating. That means in the shoulder seasons you cannot heat a north-facing bedroom while cooling a study with a south window - the system allows only one or the other. For most flats that is no problem, since the mode changes with the season, but in a house with rooms of very different orientation the limitation becomes noticeable. If that scenario is real for you, there are two answers: two separate split systems, each with its own mode, or a heat recovery system, which belongs to a different class of equipment. We always raise this before the sale, because in practice it emerges in the first October and spoils the impression of perfectly sound equipment.

Pipework: two runs from one unit

Each indoor unit has its own pair of copper pipes with its own insulation, so two runs leave the outdoor unit rather than one shared line. That affects planning: the wall needs chases for both lines, and at the exit point the arrangement has to be tidy, because two pairs of pipes in trunking look noticeably bulkier than one. There are limits on the length of each line, on the total length of all runs, and on the height difference between units - they come from the data sheet for the specific model, and we provide those figures before installation. Each indoor unit also has its own drain: two lines, each with a fall and a trap, and that is often harder than it looks during a refurbishment. The right time to plan the runs is before plastering and screeding, not after the furniture is in place.

The homes this solution suits

A two-room multi is the classic answer for a flat where a bedroom and a living room need cooling and there is nowhere - or no permission - to put two outdoor units. New buildings with technical recesses for air conditioning often allow space for only one unit, and there the alternative effectively does not exist. The second typical case is listed buildings and facades, where one unit in a rear courtyard can be approved while two on the main elevation cannot. The third is a house where two upstairs rooms are to be air conditioned without cluttering the elevation. In all of these, the 4.1 kW MU2R15 covers two medium rooms: roughly up to 20-25 square metres each at normal height and with moderate glazing.

Installing and servicing a multi system

Installing a multi demands more precision than a single split: more brazed or flared joints, a greater total pipe length and stricter requirements for evacuation. A fault at one joint affects the whole system, and the leak then has to be hunted across every line, so quality of workmanship here is worth more than a saving on the crew. Servicing consists of the same items as for an ordinary air conditioner, multiplied by the number of indoor units: filters in every room monthly during the season, coil washing once a year, pressure and drainage checks. The outdoor unit is serviced once - and that is a genuine advantage of a multi: one condenser instead of two, one point of access, one visit. Where a house has several systems, the schedules are combined into one document so that the engineer comes once rather than three times a season.

Tell us which rooms need cooling, their areas and which way the windows face, and we will choose the indoor combination for an MU2R15 and verify it against the manufacturer's table. We will also suggest the pipe routes and a position for the outdoor unit that fits your building's restrictions.

Characteristics LG MU2R15

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
14
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
545 мм.
Outdoor unit length
288 мм.
Outdoor unit width
770 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
4100 Вт.
Thermal efficiency
4700 Вт.
Find similar

Reviews about LG MU2R15 from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку