Description LG MJ07PC

The MJ07PC: 7,000 BTU for a bedroom

The MJ07PC is a wall-mounted indoor unit from LG's multi range rated at 2.1 kW cooling and 2.4 kW heating - 7,000 BTU. The casing is 818 mm wide, 316 mm high and 189 mm deep; refrigerant R32, supply 220-240 V, 50 Hz. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. The pipe diameters, maximum run length and permitted height difference for this model are checked against the data sheet before the sale, as those fields are empty on the product card. In the range it sits between the MJ05PC (item 1868) at 5,000 BTU and the MJ09PC (item 1870) at 9,000.

Why a seven is the most universal size for a bedroom

Seven thousand BTU covers a bedroom of twelve to eighteen square metres, which is the commonest bedroom size in local flats. A nine in such a room often works in bursts, because it reaches temperature quickly, while a seven holds a steadier regime and runs more quietly. For a bedroom that matters more than capacity: sleep is spoiled not by a few tenths of a degree but by changes in airflow and the noise of a fan ramping up. The exception is a room with a large west window or one on the top floor under the roof: the load there is higher and the next step up is the better choice. Another exception is a bedroom used as a study by day: then the heat from equipment and people is added and a margin is needed.

Sizing for a specific room

Area is only the first parameter, and relying on it alone means getting it wrong half the time. Orientation: a north window gives the lowest load, east brings morning sun, south and west peak during the hottest hours. Glazing: an ordinary window and half-wall glazing differ in heat gain by a factor of several. Floor: under a hot roof the load is higher, between heated floors it is lower. People and equipment: two people and a computer in a room give off hundreds of watts that an area calculation never sees. We work from these five parameters, and that is exactly why two bedrooms of the same size sometimes get different units.

Humidity and comfort in a bedroom

An air conditioner does not only lower the temperature, it dries the air, and for sleep that effect is felt just as much. A correctly sized unit works in long cycles during which moisture condenses on the coil and leaves through the drain - that is how a feeling of freshness, rather than cold, is achieved. An over-powered unit does not deliver it: it knocks the temperature down quickly, stops, and the humidity stays high, so the room feels cool and stuffy at the same time. In winter the opposite problem appears: outdoor air is dry, and heating lowers the humidity further, so during the heating season a hygrometer and, if needed, a humidifier are useful. The comfort range is roughly 40 to 60 per cent relative humidity, and it is a parameter worth measuring once in your own bedroom.

Night operation and the settings worth applying at once

After installation it is worth spending five minutes on settings that will then work for years. First, the fan mode: automatic is usually more comfortable than a fixed speed, because the system reduces the airflow itself once the temperature is reached. Second, the louvre direction: in cooling the air is sent along the ceiling so it descends without a direct draught; in heating, lower instead. Third, the timer or night mode: gradually raising the set temperature overnight gives both comfort and economy. Fourth, a moderate temperature: 24 to 25 degrees in a bedroom feels better than 20, and the morning sore throat disappears along with excessive cooling.

Where to hang the unit in a typical bedroom

In a fifteen-metre bedroom there are usually two or three possible positions, and they are not equivalent. The best is a wall from which the air travels along the room over the bed and beyond, rather than across into the opposite wall a metre away. Above the door is the classic answer for a narrow room: the unit is out of sight from the bed and the air moves into the room. The wall at the head of the bed is acceptable only with the airflow spread upwards, otherwise the cold goes straight onto the sleepers. The position to avoid is directly above the bed in a narrow room: even with vertical airflow the sense of draught remains. Drainage usually has the last word: condensate cannot be run by gravity from every wall, and that is worth checking before the position is chosen.

Filters, dust and an honest word about air cleaning

An indoor unit has coarse filters that catch dust, pet hair and larger particles. They are washed once a month during the season - the simplest and most effective thing an owner can do. But it is worth being honest: such a filter is not a medical device, does not replace ventilation and does not solve an allergy problem by itself. An air conditioner works with the air already in the room and adds no fresh air - that needs ventilation, for example the LZ-H heat recovery units (items 1888-1896) or at least regular airing. What an air conditioner genuinely does well is hold temperature and humidity, and a clean room with clean filters does the rest.

Connecting to a multi system

The MJ07PC works only as part of a multi system: an MU series outdoor unit is selected for it - from the MU2R15 (item 1852) for two indoor units to the MU5R40 (item 1859) for five. The combination is verified against the manufacturer's table, because not every set is permitted. In practice sevens most often go in bedrooms, while the living room takes an MJ12PC (item 1871) or an MA12R (item 1867) - a distribution that gives even comfort without loading the outdoor unit unnecessarily. If the rooms are used at different times, the sum of the indoor ratings may exceed the outdoor capacity, and that is fine. Everything else for installation - pipes, insulation, cable, fixings and drainage - is bought separately for the specific flat, and we send a full specification before the order.

Tell us the bedroom's area, window orientation and floor, and we will say whether 2.1 kW is enough and select the rest of the system with its outdoor unit. We will also suggest a wall position where the airflow misses the bed, and the settings for quiet operation at night.

Characteristics LG MJ07PC

Installation type
Wall
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Внутрішній блок (мульти-спліт)
BTU
7
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Indoor unit height
316 мм.
Indoor unit length
189 мм.
Indoor unit width
818 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
2100 Вт.
Thermal efficiency
2400 Вт.
Find similar

Reviews about LG MJ07PC from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку