Catalogue

LG MA12R (12,000 BTU, 3.5 kW) - square 600x600 mm indoor unit for multi systems

CL-000941
45 20000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG MA12R

The MA12R: a square unit at 12,000 BTU

The MA12R is a wall-type indoor unit for LG multi systems rated at 3.5 kW cooling and 3.9 kW heating - 12,000 BTU. The casing is the same as the smaller MA09R (item 1866): a 600 by 600 mm square, 145 mm deep. Refrigerant R32, supply 220-240 V, 50 Hz, pipes 1/4 inch (6.35 mm) for liquid and 3/8 inch (9.52 mm) for gas, maximum pipe length 15 metres, height difference up to 10 metres. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. The difference from the nine is almost a kilowatt of cooling, with identical dimensions and identical installation.

12,000 BTU in a square casing: the limit of the format

A 600 by 600 casing has a natural constraint: its coil area is smaller than that of an elongated panel of the same output. The MA12R is the top model of this format, and that is exactly what makes it interesting: it is the most capacity available without putting a long panel in the room. If more is needed, the range moves on to conventional wall units - the MJ15PC (item 1872) at 14,000 BTU, the MJ18PC (item 1873) at 18,000 and the MJ24PC (item 1874) at 24,000 - but those casings are 818 and 975 mm wide. So the choice between formats is always a trade-off: the square wins on appearance and compactness, the elongated panel on capacity and a wider airflow. For a room that genuinely needs 18,000 to 24,000 BTU a square casing is the wrong choice - it would be working at its limit.

The rooms 3.5 kW suits

The guide figure for 12,000 BTU is a room of twenty-five to thirty-five square metres at normal ceiling height with moderate glazing. That is a typical living room in a flat, a large bedroom, a study with two or three workstations. For an open-plan kitchen the calculation changes: the hob, the oven, the fridge and the open layout add load, and for a thirty-metre open space 3.5 kW may already be short. The same applies to a room with panoramic south or west windows: glazing across half a wall raises the heat gain enough that an area-based calculation understates the need by a third. If you are between the MA12R and the next step up, look not at the area but at the glazing and the number of people - they are what sets the real load.

The same design in several rooms

A multi system allows several square MA units in different rooms, and for an interior that matters: the same format in the living room and bedrooms reads as part of a plan rather than a collection of random equipment. Capacities can be mixed freely - a nine in the bedroom and a twelve in the living room is ordinary practice. Types can be mixed too: square units in the habitable rooms, for instance, and an MT09R cassette (item 1875) in a hallway with a suspended ceiling. The only constraint is the manufacturer's table of permitted combinations for the specific outdoor unit, which we check before the order. Budget is worth remembering as well: the square format usually costs more than a conventional panel of the same output, and in rooms where the unit's appearance does not matter that is a place to save.

Where to put the unit in a large room

In a thirty-metre room the point is not only to cool the air but to distribute it evenly. A square casing gives a narrower airflow than a long panel, so position matters more: the unit is placed so the air travels along the long side of the room rather than across into the nearest wall. The classic mistake is hanging it in a corner behind a wardrobe: the airflow breaks up at once, the room cools unevenly, and the owner concludes the capacity is too low. The second rule is not to aim the airflow where people sit continuously: the sofa in a living room, the desk in a study. The third is the louvres: automatic mode, spreading the air along the ceiling, gives the most even distribution, because the air descends already cooled and without a direct draught.

Heating in the shoulder seasons: 3.9 kW for a room

A heating output of 3.9 kW allows the unit to be the main heat source in September and October, March and April, when the heating is not yet or no longer on. For a living room of twenty-five to thirty metres that is enough to hold a comfortable temperature without electric convectors, which consume a kilowatt for every kilowatt of heat. There are two limitations in a multi system. The first is the outdoor temperature: a heat pump's output falls with frost, and in January the system becomes a supplementary source. The second is the shared mode: every indoor unit in the system works either on cooling or on heating, so heating the living room while cooling the study is not possible. In heating mode the airflow direction also matters: warm air rises, so the louvres are set lower than for cooling.

Control: handset, wall controller or phone

An infrared handset comes with the unit, and for most users that is enough. But there are two cases where an alternative is worth adding. The first is a flat with several units: handsets start disappearing, and a PREMTB001 wired wall controller (item 1897) in each room settles the matter for good - it looks like a thermostat, cannot be mislaid and needs no batteries. The second is remote control: the PWFMDD202 Wi-Fi module (item 1903) allows the air conditioner to be started from a phone, an hour before you get home, for instance. One technical detail matters: this module works on a 2.4 GHz network, so that band has to be enabled on the router. For families with children or elderly members a wired controller is often more practical than an app - there is nothing in it to configure.

What else to buy with an indoor unit

An indoor unit means the unit and its handset; everything else the system needs is bought separately for the specific project. You will need: an MU series outdoor unit, copper pipes of the right diameters with insulation along their whole length, the interconnecting cable, fixings, drain tubing and materials for the wall penetration. Where the drain cannot fall by gravity, a condensate pump is added - rare in a flat with units of this class, but routine in converted premises. If several units are planned, the total pipe length is calculated and the system limits checked, not just each line on its own. We always send a full specification marking what is included in the delivery and what the installation crew supplies - which removes the commonest misunderstanding when an order arrives.

Tell us the room's area, the window orientation and whether it includes a kitchen area, and we will say whether 3.5 kW is enough and select an outdoor unit for all the rooms. If the square format is only wanted in some of them, we will show a combination where appearance and budget meet.

Characteristics LG MA12R

Gas pipe
3/8 (9.52) inch/mm
Installation type
Wall
Liquid pipe
1/4 (6.35) inch/mm
Max. pipeline length
15 m.
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Внутрішній блок (мульти-спліт)
BTU
12
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Elevation difference
10 m.
Guarantee
24 months
Refrigerant
R32
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Indoor unit height
600 мм.
Indoor unit length
145 мм.
Indoor unit width
600 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
3500 Вт.
Thermal efficiency
3900 Вт.
Find similar

Reviews about LG MA12R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку