Catalogue

LG FM56AH (15.5 kW) - multi-system outdoor unit for 9 indoor units, R410A

CL-000936
325 44000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG FM56AH

The FM56AH: 15.5 kW and up to nine indoor units

The FM56AH is the most powerful single-phase multi-system outdoor unit in this LG range: 15.5 kW cooling and 17.4 kW heating, R410A refrigerant, Dual Inverter compressor. The casing is 950 mm wide, 1380 mm high and 330 mm deep; the supply is 220-240 V, 50 Hz, single phase. Manufacturer country and country of origin are Korea, the warranty is 24 months and the construction is metal with plastic parts. According to the manufacturer the system serves the largest number of indoor units in the range - up to nine - which is the scale of a whole floor or a small building. The three-phase equivalent at the same capacity is the FM57AH (item 1865), and for most sites it is the more practical choice.

The limit of a single-phase supply

15.5 kW of cooling from one phase is the upper edge of what is sensible, and that deserves saying plainly. The running current of such a machine needs its own circuit with an appropriate cable and breaker, and on a long run from the board the cross-section is increased so the terminal voltage does not dip during starting. Second, the effect on the site: one phase loaded to 15 kW skews the balance, and other users feel it - from the lighting to the till equipment. Third, available capacity: it often turns out that the contracted kilowatts simply are not there, and the answer lies not in choosing an air conditioner but in approaching the electricity supplier. If three phases exist on site, the FM57AH (item 1865) with the same 15.5 kW is the better choice; the single-phase FM56AH is for places where three phases are absent and cannot be obtained.

Nine rooms: when one system, when two

Nine indoor units on one outdoor is the technical limit of the range, and at this scale two options deserve a serious comparison: one large system or two smaller ones. One system costs less initially, occupies one position on the facade or roof and needs one supply circuit. Two systems cost more but give independent modes for different parts of the building, a far less dramatic failure and shorter runs to each group of rooms. For a building with two wings or two floors, splitting almost always wins: each unit stands nearer its own rooms, and the total pipe length does not press against the limits. We cost both options in terms of equipment and electrical requirements, so the choice is made on figures rather than on a first impression of price.

A main line across several floors

On a site this size the main line often runs vertically - down from the roof or up from a plant room - and two limits apply. First, the maximum length of the main line and the total length of all the lines after the branch joints, both taken from the specific model's data sheet. Second, the height difference between the outdoor unit and the highest or lowest indoor one, which differs depending on whether the outdoor unit is above or below. The PMBD3620, PMBD3630 and PMBD3640 distribution boxes (items 1910-1912) are placed on each floor in service space so that short lines run from them to the units. Vertical sections go in risers fixed with vibration-isolating clamps: a rigidly fixed main line carries the compressor's hum through the whole building, and complaints arrive from floors with no equipment at all.

Condensate from nine units

Nine indoor units in hot weather produce tens of litres of condensate a day, so on a site like this drainage is designed as a system rather than as a tube from each unit. The basic arrangement is a collecting drain with a continuous fall to the discharge point and a trap, which stops drain odour rising into the rooms. Where gravity will not do it - routine in an office or a clinic - ABDPG condensate pumps (item 1914) are fitted at each problem unit. Two rules prevent most leaks: no sags in a line where water can stand, and guaranteed access to every joint through inspection hatches. Before each summer the drains are flushed: a collector furred up with slime is the commonest reason for water on a suspended ceiling in July.

An uneven timetable: how the system behaves

For most of the time a site with nine rooms is not fully loaded: half the rooms in the morning, two thirds in the evening, at weekends only reception and a duty room. An inverter system in that regime reduces output and runs in long quiet cycles, so real consumption comes out well below the nameplate. There is a nuance worth knowing: if only one small unit regularly runs on a 15.5 kW system, the machine works at the very bottom of its range, which is not its most efficient state. So for rooms used constantly and separately from the rest - a server room, reception, a duty room - it sometimes makes sense to fit their own small air conditioner and leave the large system for the main timetable. That split brings both economy and redundancy: even with the multi stopped, the critical room keeps working.

The risk of a stoppage on commercial premises

Nine rooms on one outdoor unit means nine rooms that stop together. For a shop, a clinic or an office in hot weather that means not discomfort but direct loss: footfall falls in an uncooled sales area, appointments are rescheduled, staff work worse. Three things reduce the risk. First, a service contract with a fixed response time and key spares held by the supplier. Second, a capacity margin of 15-20 per cent: a system that runs at its limit through July for years wears faster. Third, separate systems for critical rooms, so that not everything depends on one compressor. These decisions are made at design stage, because after the first breakdown the options are limited to what is already installed.

What to check before ordering

Before buying a system of this scale there are five points worth settling in writing. First, the contracted electrical capacity and whether three phases exist: that determines whether this is an FM56AH at all or an FM57AH. Second, the list of rooms with areas, window orientation and operating hours: without it the capacity is a guess. Third, the position for the outdoor unit, agreed with the building owner, with access for installation and service. Fourth, the route of the main line and the positions of the distribution boxes with access through inspection hatches. Fifth, the drainage layout with its discharge points. We prepare these five points as a short specification before any pricing, because they are what decides the real cost of a working system rather than of a box of equipment.

Send the list of rooms, their areas, the operating hours and the electrical details, and we will calculate the load per zone, verify the combination of units and say whether splitting the site between two systems would serve you better. If three phases are available, we will show how the FM57AH differs in cable and board requirements.

Characteristics LG FM56AH

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
Feeding
Number of phases
1
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
53
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R410A
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
1380 мм.
Outdoor unit length
330 мм.
Outdoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
15500 Вт.
Thermal efficiency
17400 Вт.
Find similar

Reviews about LG FM56AH from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку