Description LG FM49AH

The FM49AH: three-phase 14 kW for eight indoor units

The FM49AH is an LG multi-system outdoor unit with a three-phase 380 V, 50 Hz supply, rated at 14 kW cooling and 16 kW heating. Refrigerant R410A, Dual Inverter compressor, casing 950 mm wide, 1380 mm high and 330 mm deep, metal construction with plastic parts. Manufacturer country and country of origin are Korea, with a 24-month warranty. According to the manufacturer the system serves up to eight indoor units. The single-phase equivalent at the same capacity is the FM48AH (item 1861), but there the 14 kW has to come from one phase, so where a three-phase supply exists this model is more practical in every respect, from cable size to load balance.

A balanced choice for a whole floor

14 kW across eight units is roughly 1.5 to 2 kW per room on average, and for an office floor with rooms of fifteen to twenty square metres that distribution comes out naturally. A three-phase supply removes the main headache of installations at this capacity: the current per phase is moderate, the cable is smaller and the protection works within its rating. The second advantage is less effect on the rest of the building: the lift, the servers, the kitchen and the lighting are not competing with the climate system for one overloaded phase. The third is headroom: if more equipment appears on the floor later, a three-phase supply will carry it. That is why for new installations we propose three-phase models by default and leave single-phase ones for premises where no other supply exists.

Eight zones: what the layout looks like

A typical office floor looks like this: two rooms with two desks each, one large open-plan area, a meeting room, reception, a server room, a kitchen and break area, and a corridor. Capacity is distributed by load: the open-plan area and the meeting room take the largest units, because that is where people and equipment are; the small offices take medium ones; the corridor usually manages on air spilling over, without a unit of its own. The server room is better kept off the shared system and given its own: it runs around the clock and needs cooling even in January, when the rest of the floor is being heated. The kitchen is calculated separately: the fridge, the microwave and the kettle add heat, while the smells need their own extract rather than an air conditioner. A floor like this is calculated room by room - multiplying total area by a coefficient always gets it wrong by a unit or two.

A sales floor with an entrance

For a shop the main problem is not area but the door: every opening lets in hot outside air, and in summer that loads the system noticeably. Where the entrance opens hundreds of times a day, an air curtain over the door saves more than an extra kilowatt of cooling, and we always recommend costing the two together. The second feature is air distribution: units in the sales area are positioned so the airflow does not blow onto the till or onto a salesperson standing in one place for eight hours. The third is displays and lighting: refrigerated cabinets and spotlights over the goods add heat that an area-based calculation does not see. The fourth is the timetable: a shop open until ten at night peaks in the evening, when the facade gives back the heat it stored during the day, so the system has to keep its margin for exactly that period.

Clinics, salons, rooms where people are received

In rooms where visitors are received, the climate acquires extra requirements. First, no direct airflow onto a person: cold air in a patient's or client's face spoils the impression faster than heat does, so units are positioned with the couch, chair or desk in mind. Second, hygiene: indoor filters in such rooms are cleaned more often than the standard regime requires, and once a year the coil and the drain tray get a deep clean. Third, quiet: in a room where you talk to a client the unit's noise level matters, and cassette models with even distribution are usually more comfortable there than wall units. Fourth, fresh air: an air conditioner does not ventilate, and rooms with people present all day need separate ventilation - the LZ-H heat recovery units (items 1888-1896) exist for that.

Metering and control where there are tenants

Where the rooms on a floor are occupied by different tenants, the question arises of how to divide consumption. Splitting metering completely on a single multi system is technically awkward, so in practice either the lease fixes a share by floor area, or each tenant gets a separate system. The middle path is the AC Smart 5 central controller (item 1907), which sees the state and running hours of every indoor unit and lets the manager set schedules and limits for each room. Networking uses the PI485 PMNFP14A1 module (item 1904). If tenants change often, the split is worth considering at design stage: reworking the system later costs far more than specifying two smaller machines from the start.

Installing while the premises are in use

A system for eight units is rarely installed in an empty space - usually the office or shop keeps trading. That calls for planning: the noisy stages, chasing walls, drilling slabs, lifting the outdoor unit into place, are moved to weekends or to night hours where the building allows it. Second, dust: running pipework in a suspended ceiling raises dust across the whole space, so work areas are sheeted and equipment and papers are cleared away. Third, sequence: it is better to commission the system zone by zone, so some rooms already work while the rest is finished. Fourth, access: the installers need a clear route to the pipework and to the outdoor unit, and if that route crosses a room with customers it is agreed in advance. The realistic programme for such a system is several days of active work plus a day for commissioning.

Headroom for expansion, and an honest view of the limits

When premises are being planned there is always a temptation to buy a system with margin for the future. The rule is simple: margin makes sense when the expansion is specific - a known room, a known date, a known load. If it is only a maybe someday, surplus margin works against you: a large machine runs permanently at the bottom of its range and money is frozen in capacity nobody uses. The technical constraint is worth knowing too: unused ports are capped per the manual, and connecting a new unit a year later is a full visit with pressure testing, evacuation and a recalculated charge. If the room count exceeds eight, the right answer is a second separate system rather than a hunt for an outdoor unit with a ninth port.

Describe the floor or the premises - rooms, areas, how many people, operating hours - and we will calculate the load per zone, verify the combination of units and select the branch joints and distribution boxes. If the rooms are let to different tenants, we will propose an arrangement in which metering and control do not become a monthly argument.

Characteristics LG FM49AH

Installation type
Зовнішній блок
Electrical properties
Current frequency
50Hz
High-voltage
380В.
Feeding
Number of phases
3
General characteristics
Appointment
Мульти-спліт (зовнішній блок)
BTU
48
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Guarantee
24 months
Refrigerant
R410A
Type
Мульти-спліт
Manufacturer
LG
Overall dimensions
Outdoor unit height
1380 мм.
Outdoor unit length
330 мм.
Outdoor unit width
950 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
14000 Вт.
Thermal efficiency
16000 Вт.
Find similar

Reviews about LG FM49AH from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку