LG CT24R (24,000 BTU, 7 kW) - 840x840 mm four-way cassette with runs up to 30 m
Description LG CT24R
The CT24R: a four-way 7 kW cassette
The CT24R is a cassette indoor unit in LG's R32 semi-industrial range, rated at 7 kW cooling and 8 kW heating. Unlike the compact models of the series it has an 840 by 840 mm body on plan and is only 204 mm deep, runs on 220-240 V, 50 Hz, uses R32 and works with a Dual Inverter in the pair. Pipework is 1/4 inch liquid and 5/8 inch gas, the maximum run is 30 metres and the maximum height difference 15 metres - twice what the compact cassettes of the same series allow. Manufacturer country and country of origin are Korea, the warranty is 24 months and the casing is metal with plastic parts. The decorative panel is bought separately, and for the 24-60 kBTU range it is a different model - the PT-MCGW0 (item 1916), not to be confused with the panel for compact cassettes.
An 840 mm body in a 600 mm ceiling grid
Going from 570 to 840 mm means the cassette no longer drops into the place of one ceiling tile: it occupies an area where the grid profiles have to be cut and retied. In a mineral tile ceiling a separate frame of main runner is built for the unit so that the panel's weight goes into the hangers rather than onto the neighbouring tiles, and doing that while the ceiling is being installed is ten times easier than dismantling a finished plane later. In plasterboard the opening is cut to the template in the installation manual and the perimeter is reinforced with CD profile, because the panel measures about 950 by 950 mm externally and a plasterboard edge will not hold it. The depth is pleasantly small - just 204 mm, less than the compact CT18R - so a void of roughly 270-290 mm covers it including drain fall and insulation. That is precisely why the CT24R often goes where the ceiling is low but the capacity is needed: it is undemanding in height and demanding in plan.
30 metres of pipe and 15 of lift: room to design
Doubling the pipe limit to 30 metres and the height difference to 15 fundamentally changes where the outdoor unit can live. Compact cassettes are effectively tied to the nearest facade, while a CT24R lets you put the outdoor unit on the roof of a three-storey building, in a courtyard, or behind a blank wall away from the neighbours' windows and the shop front. That is not only about appearance: a unit on the roof picks up less road dirt, is harder to damage and does not blow warm air across the entrance to the premises. The price is a more demanding installation - a long run needs an accurate calculation of additional refrigerant charge, proper oil traps on vertical sections and thorough evacuation, because every extra metre raises the cost of a mistake. We always advise against choosing the maximum simply because it is permitted: 15-20 metres with a margin behaves better than 30 at the edge of the data sheet.
The 5/8 gas line and the pipework left by the old unit
A 5/8 inch gas line is noticeably larger than the 3/8 of the smaller models in the series, and that follows directly from the capacity: a greater volume of vapour has to travel with an acceptable pressure drop. In practice the question comes up in one specific situation - when copper from an older air conditioner is already in the building and the temptation is to reuse it. Sometimes that works, but only after three checks: whether the diameters suit the new pair, whether the line is free of damage and flattened sections, and whether it can be properly purged and evacuated after the previous refrigerant and mineral oil. If the old line is narrower than required - and 1/2 inch instead of 5/8 is a common find - the saving turns into lost capacity and extra load on the compressor, a risk out of all proportion to the cost of new copper. We settle this before quoting and say plainly when the old run should be stripped out.
Seven kilowatts in a sales floor: where it fits
7 kW of cooling covers a retail floor or an open-plan office of roughly 60-75 m² at normal ceiling height with moderate glazing. Four-way discharge from the centre of the ceiling works particularly well where people move across the whole area - a shop, a pharmacy, a bank branch - because no one direction is blown at continuously. In a restaurant such a cassette serves the dining room, but it is deliberately kept away from a bar with a hot display: steam and grease shorten the coil's service interval several times over. For a densely occupied room - a gym, a lecture room for 25-30 people - 7 kW is still realistic, but the calculation then has to include the heat the people themselves give off, which in an active hall is comparable with the gain through the windows. In a hall longer than about 12 metres a single cassette can no longer keep the distribution even, and two units or a ducted layout with several grilles deserve a look.
Against the CM24R ducted and the UV24R ceiling unit
This catalogue offers three ways to get the same 7 kW: the CT24R cassette, the CM24R ducted unit (item 1829) at 270 mm deep, and the UV24R ceiling-suspended unit (item 1843). The cassette wins where a ceiling is already suspended and the look has to be tidy with even distribution: all you see is a square panel, and the air goes four ways. The ducted unit is better where the space is awkwardly shaped or the air has to reach two or three zones through separate grilles, though it needs room for ductwork and a proper design. The ceiling-suspended unit is the choice for a hall with no suspended ceiling at all: it mounts in the open below the slab, throws a long horizontal stream along the room and costs less to install. Our rule: a square room with a finished ceiling takes the cassette, complex geometry with ducts takes the ducted unit, bare concrete takes the ceiling-suspended one, and never the other way round.
What to settle during the fit-out, not after it
A CT24R is equipment you plan together with the electrics and the ceiling, because three things are impossible or very expensive to change afterwards. The first is position: an 840 mm panel has to sit within the ceiling composition alongside the luminaires and detectors rather than being squeezed between them at the last moment. The second is drainage: even with a built-in pump the line has to go somewhere, and that route is agreed with the plumbing before the ceiling closes, with a separate ABDPG pump (item 1914) where the geometry is difficult. The third is power and control: a supply cable and the wired controller cable both run to the unit, and the chase for the controller is cut with the rest of the electrical work, or a surface trunking on freshly painted wall becomes a permanent reminder of the rush. With those three points resolved on the drawing, installing the cassette becomes a single working day without surprises.
Send us a floor plan with the ceiling layout and we will tell you whether a CT24R fits your grid, then quote the set with panel, outdoor unit and controller. If it does not, we will price the ducted or ceiling-suspended alternative at the same capacity.