LG CT12R (12,000 BTU, 3.5 kW) - 570x570 mm cassette indoor unit for rooms up to 35 m²

CL-000909
44 29600 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG CT12R

The CT12R: 3.5 kW in the same casing

The CT12R is a cassette indoor unit from LG's R32 semi-industrial range rated at 3.5 kW cooling and 4 kW heating. The casing repeats the smaller model exactly: 570 by 570 mm on plan, 214 mm deep, 1/4 inch liquid and 3/8 inch gas pipework, a 15 metre maximum run and up to 10 metres of height difference. Supply is 220-240 V, 50 Hz, the refrigerant is R32, the compressor in the pair is a Dual Inverter, the casing is metal with plastic parts, manufacturer country and origin are Korea and the warranty is 24 months. The decorative panel is not included: for 09-18 kBTU units it is the PT-QAGW0 (item 1915), ordered together with the cassette. The matching outdoor unit here is the UU12WR (item 1813) at the same 3.5 kW cooling and 4 kW heating.

Twelve against nine: where the line falls

The CT09R and the CT12R differ in capacity alone - casing, panel, ceiling opening, pipework and the installers' working day are identical to the millimetre. That means choosing between them is not a choice between two projects but only between indoor and outdoor units, with every associated installation cost staying where it was. The working guide is this: the nine covers 20-25 m² at ordinary load, while the twelve covers 30-35 m², or the same 25 m² with a large south-facing window, equipment, or six to eight people in the room all day. When the calculation lands somewhere in between, at around 3 kW, we suggest the larger model - a few hundred watts of margin cost less than rework if the summer proves the capacity short. The reverse rule holds too: putting a twelve into a 15 m² room is a mistake, and the reason is not price but the way it then runs.

Why an oversized unit dehumidifies badly

An air conditioner removes moisture only while its coil is cold and air passes through it for long enough. An oversized machine pulls the temperature down in a few minutes, switches off and never gets to condensing much water - the room ends up cool and clammy at once, which is the commonest source of complaints about air feeling unpleasant. A Dual Inverter in the pair softens the effect because it can run at reduced output instead of cycling on and off, but it too has a floor below which it will not modulate. That is why a cassette is sized from a heat gain calculation rather than from a wish to have something in reserve. In a room with a steady flow of people - a training room, a treatment room, a cafe - moisture from breathing and perspiration adds real load, and a twelve over 30 m² earns its place; in a quiet 20 m² office it would run in short bursts.

Where this model belongs

3.5 kW suits a retail section or pharmacy of around 30-35 m², a training room for 10-12 people, a manager's office with a meeting corner, or a salon with two chairs. In every one of those, evenness is the point: the front row should not be blown at, nor the client in the chair, nor an open display holding temperature-sensitive stock. Four streams from the centre of the ceiling, each with its own louvre adjustment, let you close off the awkward directions without giving up capacity. Where there is refrigeration in the room - pharmacy fridges, drinks cabinets - the heat from their compressors is counted separately, because they run around the clock and add noticeable load. For a room with a street door, infiltration goes into the calculation as well: a door left open can swallow a kilowatt and more.

Heating from the ceiling: the part nobody mentions

In heating mode a cassette has an inherent handicap: warm air is lighter than cold and wants to stay under the ceiling, so it has to be pushed down actively. In practice that means the louvres are set almost vertical in winter and the fan runs faster than in summer, with the noise level rising accordingly. In a room 2.7-3 metres high the difference is barely noticeable, but in a hall four metres high part of the heat settles above head height, and a cassette as the main heat source loses there to a wall or floor-standing unit. The second factor is the outdoor unit's defrost cycles: a few minutes without heat on a frosty day are noticeable when the air conditioner is the only heat source in the room. So we say it plainly - a cassette carries the shoulder seasons and keeps a room comfortable, but full heating duty is assigned to it only after a heat loss calculation.

Installation: the opening, the reinforcement and filter access

In a mineral tile ceiling the cassette takes the place of one module; in plasterboard the opening is cut to the template and the perimeter reinforced with profile. Above the unit you need roughly 280-300 mm of void: 214 mm of casing plus resilient mounts, drain fall and pipe insulation. The filter withdraws downwards through the panel grille, so routine access does not require a hatch - but service does, and a hatch next to the cassette is planned from the start so that the tray and the condensate pump can be reached once a year. The suspension rods anchor into the structural slab, not into the ceiling frame: that frame is designed for a tile and a light fitting, not for a unit with a coil in it. Levelling is mandatory and is checked with a spirit level rather than by eye, because a few millimetres of tilt turn into litres of water over the edge of the tray.

Control, and what to fit in a public room

For an office or a classroom the standard is a wired PREMTB001 panel (item 1897) on the wall beside the light switch: it cannot be mislaid and needs no batteries. Where the room is open to the public, a wall panel tends to become an object of experiment, and the wireless PWLSSB21H (item 1901) kept by the manager makes more sense. If the unit has to be operated from elsewhere - warming the room before the staff arrive, for instance - the PWFMDD202 Wi-Fi module (item 1903) and the LG ThinQ app do the job, remembering that the module only sees a 2.4 GHz network. Once a building holds four or five such cassettes, an AC EZ central controller (item 1905) for up to 32 units is more practical: it shows the state of every machine and can limit the setpoint range so that nobody asks for 28 degrees in January. The choice of controller affects running costs more than it looks - half the wasted electricity in offices comes from habits rather than from equipment.

Send us the floor area, the ceiling height and how many people use the room, and we will work out whether the CT12R is enough or the next size up is wiser. The panel, the controller and the outdoor unit are quoted as one set so that nothing is missing on installation day.

Characteristics LG CT12R

Gas pipe
3/8 (9.52) inch/mm
Installation type
Касетний
Liquid pipe
1/4 (6.35) inch/mm
Max. pipeline length
15 m.
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Напівпромисловий
BTU
12
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Elevation difference
10 m.
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
214 мм.
Indoor unit length
570 мм.
Indoor unit width
570 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
3500 Вт.
Thermal efficiency
4000 Вт.
Find similar

Reviews about LG CT12R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку