LG CL24R (24,000 BTU, 7 kW) - low-static ducted indoor unit 190 mm high
Description LG CL24R
The CL24R: 7 kW in an 1100 mm casing
The CL24R is the most powerful low-static ducted unit of the CL series: 7 kW cooling, 8 kW heating. The height stays at 190 mm and the depth at 700 mm, while the width grows to 1100 mm, because this output needs a longer coil and a larger fan assembly. Per the card the circuit pipework is 1/4 inch (6.35 mm) liquid and 5/8 inch (15.88 mm) gas; the maximum pipe run is 30 metres and the height difference up to 15 metres. The supply is 220-240 V, 50 Hz, the compressor in the pair a Dual Inverter, the refrigerant R32, the manufacturer country and country of origin Korea and the warranty 24 months. This is an indoor unit: it needs pairing with an outdoor unit of matching output.
A 30 metre run: freedom in siting the outdoor unit
The card's limits of 30 metres of run and 15 metres of height difference are twice those of the smaller models in the series, and in practice they change the logic of the design. The outdoor unit can be placed not where it is nearest but where it belongs: on the roof rather than the facade, in a courtyard rather than outside a window into the hall, on a plant platform behind the building. For a leased space in a shopping centre that is often the only way to agree the installation with a landlord who does not allow units on the main facade. The price of length is the refrigerant top-up: beyond the base run a rate per metre is added, and at 25-30 metres that is already a noticeable quantity, recorded in the documents without fail. The second point is the fall and the oil traps at a large height difference: without them the oil does not return to the compressor, and the system fails after months rather than at once.
Why the gas pipe is 5/8 and the liquid pipe 1/4
Asymmetric diameters puzzle anyone seeing a circuit for the first time, but the logic is simple: the liquid line carries refrigerant in its liquid phase, dense and compact, while the gas line carries vapour whose volume is tens of times greater for the same mass. The liquid line therefore stays slim even at 7 kW, while the gas line grows to 5/8 inch so as not to create resistance and pressure loss. The practical consequence for installation: both pipes are insulated separately, each in its own insulation, rather than together in one sleeve. Wrapped together they exchange heat, the refrigerant in the liquid line gains superheat and the system loses output - the classic error of a hasty installation. The insulation thickness for the gas line is greater than for the liquid line, and it runs the whole length without breaks, including the sections inside a wall.
Air distribution at 7 kW
The airflow of a 7 kW unit calls for four to six supply grilles, and the layout is built from a main duct of 300 by 150 mm or more, or 250 mm round and up, with a branch to each grille. The return duct must be generous: at this capacity two return grilles are often fitted, or one large one with a filter reachable through a hatch. Balancing the layout is mandatory: without dampers on the branches and airflow measurements, the grille nearest the unit takes three times more air than the farthest, and the zone beneath it freezes while the far end of the hall stays warm. For a long narrow space - a narrow shop, a corridor office - the main duct runs the full length with the grilles evenly spaced rather than clustered near the unit. This model's static pressure is low, so the total length of main duct with branches should stay within 10-12 metres with a minimum of bends.
A space of 60-75 m²
7 kW is the size of a 60-75 m² sales floor, an office of 10-12 workstations, a restaurant room with 25-30 covers, a fitness studio, a medical centre with several rooms on the same regime. For a room with seating it is not only the area that counts but the people: each visitor adds roughly 100-120 watts of heat, so a full house of 30 is already 3-3.5 kW from people alone. For an office the equipment counts in the same way: 12 workstations with monitors are about 1.5-2 kW of constant load. That is exactly why an area-based formula is out by a factor of two in commercial premises, and the selection is made from a heat gain calculation. We calculate this from the data you provide: area, height, glazing with its orientation, the number of people and a list of equipment.
Pairing with an outdoor unit
The CL24R pairs with the UU24WR outdoor unit (item 1815) at 7 kW cooling and 8 kW heating, single-phase, in a casing of 950 by 834 by 330 mm. The current of such a system at 220-240 V is roughly 11-13 A, so a dedicated 2.5 mm² copper circuit with its own breaker is needed, and the headroom in the authorised capacity is worth checking in advance. The circuit runs on R32; the card's limit of 30 metres on the indoor unit should be cross-checked against the outdoor unit's card and the combination table, because the limit for the pair is the lesser of the two. On a long run, oil traps and an accurate top-up calculation are mandatory. We always confirm the final combination against LG's documentation - we do not propose a pair that is absent from it.
Which jobs it fits and where it is out of place
The CL24R suits a space of 60-75 m² with a suspended ceiling and at least 280-320 mm of void, where the equipment has to be fully concealed and the outdoor unit sits up to 30 metres away. It works well in elongated halls, where one cassette does not cover the space but a ducted main with evenly spaced grilles does. Where the model is out of place: spaces without a suspended ceiling; complex layouts with a long branched network and high resistance - those need the medium-static CM24R (item 1829) at the same capacity; spaces divided into zones at different temperatures. A kitchen, a laundry or a production area with high heat gains needs a separate calculation, and it often turns out that 7 kW is not enough even for 40 m². If more than 7 kW is needed in one circuit, you move to the UM series - the UM36R (item 1830) at 10 kW and above.
How it differs from neighbouring models in this catalogue
The CL18R (item 1826) is 5 kW in the 900 mm casing: a step down, enough for a hall of 45-55 m². The CM24R (item 1829) has the same 7 kW output but is 270 mm high with medium static pressure for long ductwork; with a complex network that is the sounder choice. The CM18R (item 1828) is 5 kW medium-static. If there is no suspended ceiling, 7 kW is available from the CT24R cassette (item 1837) at 840 by 840 mm or the MJ24PC wall unit of a multi-split system (item 1874). The outdoor unit for this model is the UU24WR (item 1815), the same one that works with the CT24R and CM24R, so the indoor type can be changed without revisiting the outdoor side.
Send us the layout, the ceiling height, the number of people and a list of equipment - we will check whether 7 kW is enough and design the ductwork for the CL24R.
Characteristics LG CL24R
Reviews about LG CL24R from real users
No reviews found