Catalogue

LG CL12R (12,000 BTU, 3.5 kW) - low-static ducted indoor unit 190 mm high

CL-000899
49 72000 ₴
Out of stock
14 days
Our advantages
Delivery terms and cost
Payment options

Description LG CL12R

The CL12R: a 3.5 kW ducted unit

The CL12R is a ducted indoor unit of LG's R32 semi-industrial series: 3.5 kW cooling, 4 kW heating. The casing is the same as the smaller model's - 900 mm wide, 700 mm deep, 190 mm high, metal with plastic elements, supply 220-240 V, 50 Hz. Per the card the circuit pipework is 1/4 inch (6.35 mm) liquid and 3/8 inch (9.52 mm) gas; the maximum pipe run is 15 metres and the height difference up to 10 metres. The manufacturer country and country of origin are Korea, the warranty 24 months and the compressor type in the pair a Dual Inverter. This is an indoor unit that works only paired with an outdoor unit of matching output.

Ductwork: material, insulation and condensation

A duct in a ducted system is not merely a pipe but, physically speaking, part of the cooling circuit: air at 12-16 degrees passes through it, and condensation inevitably forms on the outer surface of an uninsulated duct. Above a suspended ceiling that ends in stained tiles, and in a plasterboard structure in damp and mould that stays invisible from outside for months. Ducts are therefore insulated completely: a rigid galvanised duct is wrapped in 20-30 mm of closed-cell insulation, while flexible ducts are bought pre-insulated and their joints sealed. The second point is the airtightness of the ducts themselves: leaky joints lose up to 10-20 per cent of the airflow, and the cooling goes into the ceiling instead of the room. The correct method is simple: joints taped with adhesive aluminium tape, clamps on flexible duct, continuous insulation with no cuts at the bends.

One unit for two rooms

The CL12R is enough to serve, say, an adjacent office and meeting room: the duct is branched to two supply grilles with the return placed in the corridor or in one of the rooms. The limitation here is fundamental: there is one thermostat temperature, and the unit works from the sensor in the return air rather than from each room separately. If three people with computers sit in one room and one person in the other, the cooling will distribute itself by duct resistance rather than by need - and one of the rooms will end up overcooled. This is partly solved with manual volume dampers on the branches, set once against the real load; automatic zoning with actuators is not provided for on a unit like this. A two-room layout is therefore used where the rooms are alike in purpose and occupancy - two offices, two hotel rooms, a shop floor and a back room.

Noise and where it originates

The unit itself above the ceiling is quiet, and complaints about noise in ducted systems almost always concern the ductwork rather than the fan. The main sources are these: high velocity at a grille whose free area was undersized; flexible duct whistling at a tight bend or crushed during installation; a rigid hanger transmitting vibration into the ceiling. For a bedroom, a hotel room or an office the velocity at the supply grille is kept at 1.5-2 metres per second, which is practically inaudible; for a sales floor 2.5-3 is acceptable. Flexible connectors between unit and duct, smooth radiused bends and an adequate main duct section solve the problem at installation stage, whereas once the ceiling is closed up all that remains is to reduce the fan speed and lose capacity. If the space demands quiet, that is worth discussing before the ductwork is designed rather than after the first night.

Filtration and fresh air

The standard filter of a ducted unit is there to protect the coil rather than to clean the room's air, and its grade is adequate for dust but not for fine particles. If better filtration is needed it is placed not in the unit but in the return duct - a cassette filter in a box ahead of the unit, reachable through the same inspection hatch. The second practical point: a ducted scheme allows fresh air to be mixed in, and that is a genuine difference from wall units, which only recirculate. For a meeting room or an office with several people, even 20-30 per cent fresh air in the supply makes a noticeable difference to how everyone feels by the end of the working day. But the mixing has to be calculated: in winter cold outside air without preheating can ice up the coil, so such a scheme is designed separately, often with a heat recovery ventilation unit such as those of the LZ-H series.

Pairing with an outdoor unit

The CL12R pairs with the UU12WR outdoor unit (item 1813) at 3.5 kW cooling and 4 kW heating. The circuit runs on R32 with 1/4 and 3/8 inch pipes and a card limit of 15 metres of run and 10 metres of height difference - enough to place the outdoor unit on a balcony, on a facade or on the roof of a single-storey building. A run beyond roughly 7-10 metres calls for a top-up at the manufacturer's rate, and the actual quantity is recorded in the handover documents. The outdoor unit is single-phase; the current of such a system is small, and a dedicated circuit with a breaker is quite sufficient. We verify the final combination against LG's compatibility table - we do not propose a pair that is absent from the manufacturer's documentation.

Which jobs it fits and where it is out of place

The CL12R suits a space of roughly 28-38 m² with a suspended ceiling: an office, a meeting room, a shop, a salon, or two small adjoining rooms on the same regime. It is often chosen for hotels and apartments where it matters that the equipment stays unobtrusive and where there is void above a bathroom or in a corridor to house the unit. Where the model is out of place: spaces without a suspended ceiling, or with less than 280 mm of void; layouts with long branched ductwork, which need the medium-static CM series; spaces that need a separate temperature in each zone. For a flat with three or four rooms that each have to run independently, a single-unit ducted scheme is unsuitable - a multi-split system is used there. And if the area exceeds 40 m² or there is large south-facing glazing, 3.5 kW will not be enough.

How it differs from neighbouring models in this catalogue

The CL09R (item 1824) is the same casing at 2.5 kW: a step down for a smaller space. The CL18R (item 1826) is 5 kW in the 900 by 700 by 190 mm envelope, and the CL24R (item 1827) is 7 kW in a wider 1100 mm casing with a run of up to 30 metres. The CM18R (item 1828) and CM24R (item 1829) are medium-static, 270 mm high, for complex duct layouts. If there is no suspended ceiling, the alternatives at the same output are the CT12R cassette (item 1835) or the MJ12PC wall unit of a multi-split system (item 1871). The outdoor unit for this model is the UU12WR (item 1813); the same unit works with the CT12R cassette, so the indoor type can be chosen after the location of the outdoor unit is settled.

Describe the space and the ceiling - we will work out a duct layout for the CL12R, select grilles and say whether fresh-air mixing is worth adding.

Characteristics LG CL12R

Gas pipe
3/8 (9.52) inch/mm
Installation type
Канальний
Liquid pipe
1/4 (6.35) inch/mm
Max. pipeline length
15 m.
Electrical properties
Current frequency
50Hz
High-voltage
220 - 240В.
General characteristics
Appointment
Напівпромисловий
BTU
12
Compressor type
Dual Inverter
Country of origin
Корея
Country of origin
Корея
Elevation difference
10 m.
Guarantee
24 months
Refrigerant
R32
Type
Split system
Manufacturer
LG
Overall dimensions
Indoor unit height
190 мм.
Indoor unit length
700 мм.
Indoor unit width
900 мм.
Physical properties
Material of execution
Combination of metal and plastic
Thermal properties
Cooling capacity
3500 Вт.
Thermal efficiency
4000 Вт.
Find similar

Reviews about LG CL12R from real users

No reviews found

Store addresses
Working hours
Телефон
Availability
Maybe it will interest you
  • Recently viewed
  • Most popular
  • Sale
 
 
 
Швидко і якісно достявляємо

Наша компанія виконує доставку по всій Росії і ближньому зарубіжжі

Гарантія якості і сервісне обслуговування

Ми пропонуємо тільки ті товари, в якості яких ми впенені

Повернення товару протягом 30 днів

У вас є 30 днів, для того щоб протестувати вашу покупку